Homing

Requirements

  • The technology module is in the STANDBY state.

  • The axes and the axis group are enabled (xReadyForMotion = TRUE).

  • No error is active (xError = FALSE)

Execution

With a rising edge (FALSEรคTRUE) at input xGroupHomeExecute, homing is started (output xGroupHomeActive = TRUE). The axis group performs homing until the reference position for the axes is reached.

Depending on the connected axis group, only the real axes A1 ... A6 and Aux1 are referenced. Only the axes are referenced in the order as specified via the aeHomingOrder parameter.

After reaching the reference switches of the axes, xIsHomed = TRUE is switched. On successful completion of the homing run, xHomingDone = TRUE changes.

If xHomeExecute = FALSE is set, then the state STANDBY is changed and xHomingDone = FALSE is set.

Aborting the reference run

The function is aborted via the xGroupAbort input. The reference run is not interrupted if xGroupHomeExecute = FALSE is set prematurely.

Parameters to be set

  • The parameters for homing are located in AXIS_REF in subindex 70 ... 80.

  • The parameters from the PLC program can also be written via the function block L_MC1P_SetBasicParameter.

The TM cannot execute a reference run if no homing sequence is defined. The homing sequence is defined by the parameters in subindex 70 ... 82 of the axis group.