Stopping a path (Halt)
Prerequisite
-
The axes are enabled (xReadyForMotion = TRUE).
-
A web is run.
Execution
With a rising edge (FALSEรคTRUE) at input scCtrlCoordinatedMotion.xGroupHaltExecute the current motion of the axis group is interrupted and brought to a standstill with the deceleration ramp. The deceleration ramp is located in the axis group in subindex 190 and the jerk in subindex 191.
The technology module changes to the "STOP" state (display at eTMState output). After reaching standstill, the xPathHold output is set = TRUE. This indicates that the current position in the profile has been noted. Thus, the path can be continued at this position.
The technology module changes to the STANDBY state as soon as the standstill is reached and the input scCtrlCoordinatedMotion.xGroupHaltExecute = FALSE is set. The TM may continue the path or calculate and execute a new path.
The Conveyor belt is to be continued at its stopping point
If the output xPathHold = TRUE is active, the "Finish" function can be activated. In this case, the marked path is run to the end.
The driving profile is to be canceled
With the new command or functions like Move xMoveLinAbsExecute the held path is discarded. The status xPathHold = FALSE is set.
Parameters to be set
-
The parameters for the xGroupHaltExecute are located in the axis group in subindex 190 and 191.