QSP application
Prerequisite
-
The axes are enabled (xReadyForMotion = TRUE).
Execution
With a rising edge (FALSEรคTRUE) at input xQSPApplication, the current motion of all real axes (A1 to A12) is interrupted individually - regardless of the path - and brought to a standstill based on their last current velocity value at the QSP application deceleration ramp.
|
The coordinated movement is dissolved. The path is left. |
The parameter for the QSP application delay ramp is set in the AXIS_REF.
Driving diagram
The technology module changes to the STOP state (displayed at the eTMState output). The state is maintained until the standstill of all axes is reached and the input xQSPApplication = FALSE is set.
Continuing the movement via xFinish is not possible after QSP. The path calculated up to that point is discarded and thus cannot be moved.
Parameters to be set
-
The parameters for the QSP Application are located in the AXIS_REF in subindex 48 and 49.
-
The parameters from the PLC program can also be written via the function block L_MC1P_SetBasicParameter.