L_TB2P_scCtrlBasicMotionExtended

L_TB2P_scCtrlBasicMotionExtended

BOOL

-

xEnableOperation

scCtrlBasicMotion

-

L_TB2P_scCtrlBasicMotion

BOOL

-

xResetError

BOOL

-

xAbort

BOOL

-

xJogPos

BOOL

-

xJogNeg

BOOL

-

xHomeExecute

LREAL

-

lrOverride

LREAL

-

lrVel

LREAL

-

lrAcc

LReAL

-

lrDec

LREAL

-

lrJerk

MC_DIRECTION

-

eDirection

MC_TRIGGER_REF

-

scHomeExtTP

BOOL

-

xEnableNegative

BOOL

-

xEnablePositive

LREAL

-

IrOverrideAcc

LREAL

-

IrOverrideJerk

BOOL

-

xDisableSWLimit

BOOL

-

xContinuousUpdate

BOOL

-

xHalt

BOOL

-

xFinishPositioning

BOOL

-

xMoveVelExecute

LREAL

-

xMoveAbsExecute

BOOL

-

xMoveRelExecute

LREAL

-

IrPos_Dist

BOOL

-

xHomeAbsSwitch

BOOL

-

xResetHomePosition

BOOL

-

xHWLimitPos

BOOL

-

xHWLimitNeg

Identifier

Data type

Description

xEnableOperation

BOOL

TRUE

The axis is switched ready for operation.

The controller release is issued.

xResetError

BOOL

The input is edge-controlled and evaluates the rising edge.

FALSEäTRUE

Reset the axis or software error.

xQSPApplication

BOOL

The input is level-controlled and evaluates the high level.

TRUE

Active movement is cancelled and the axis is brought to a standstill via the QSPApplication stop ramp.

  • A change is made to the "STO" status.
  • The technology module remains in the STOP state as long as xQSPApplication= TRUE is set.

xAbort

BOOL

TRUE

Active movement is cancelled and the axis is brought to a standstill via the profile deceleration(scPar.IrDec).

  • A change is made to the STOP state.

The deceleration ramp can be cancelled by commanding a new movement (e.g. xMoveVelExecute).

  • Cancellation and termination of positioning

xJogPos

BOOL

The input is level-controlled and evaluates the high level.

  • Hand cycling (jogging)

TRUE

Move the axle in the positive direction (manual travel).

If xJogNeg is also TRUE, the error message "InvalidInputJogPosJogNeg" is output via the eErrorID output and the axis stops.

xJogNeg

BOOL

The input is level-controlled and evaluates the high level.

  • Hand cycling (jogging)

TRUE

Move the axle in the negative direction (manual travel).

If xJogPos is also TRUE, the error message "InvalidInputJogPosJogNeg" is output via the eErrorID output and the axis stops.

xHomeExecute

BOOL

The input is edge-controlled and evaluates the rising edge.

  • Homing

FALSEäTRUE

Start referencing.

The function is cancelled via the xHalt input.

lrOverride

LREAL

The specified target speed is multiplied by the factor lrOverride (e.g. an override value of 0.5 generates half the target speed)

  • Value range: 0 ... 1.0
  • Initial value: 1.0

Note: The transfer of the value is independent of the status in xContinuousUpdate.

lrVel

LREAL

Speed for movements (MoveAbs, MoveRel, MoveVel) that are ordered via the scCtrlBasicMotion structure.

  • Unit: units/s
  • Initial value: 3600

lrAcc

LREAL

Acceleration for movements (MoveAbs, MoveRel, MoveVel) that are ordered via the scCtrlBasicMotion structure.

Specification of the maximum change in speed with which acceleration should take place.

  • Unit: units/s2
  • Initial value: 36000

lrDec

LREAL

Delay for movements (MoveAbs, MoveRel, MoveVel) that are ordered via the scCtrlBasicMotion structure.

Specification of the maximum change in speed to be used for deceleration to a standstill.

  • Unit: units/s2
  • Initial value: 100

lrJerk

LREAL

Jerk for movements (MoveAbs, MoveRel, MoveVel) that are ordered via the scCtrlBasicMotion structure.

  • Unit: units/s3
  • Initial value: 0

eDirection

MC_DIRECTION

Movement direction for movements (MoveAbs, MoveVel) that are commanded via the scCtrlBasicMotion structure:

  • mcCurrentDirection: Maintain current direction (only for modulo axes)
  • mcPositiveDirection: Positive direction
  • mcNegativeDirection: Negative direction
  • mcShortestWay: Shortest path (only for modulo axes)
  • Initial value: mcPositiveDirection

MC_TRIGGER_REF

  • L_MC1P_MotionControlBasic for single axes

  • MC_TouchProbe

xEnableNegative

BOOL

TRUE

Release process in negative direction.

  • Initial value: TRUE

xEnablePositive

BOOL

TRUE

Release process in positive direction.

  • Initial value: TRUE

lrOverrideAcc

LREAL

Factor for the global acceleration override

  • Value range: 0 ... 1.0
  • Initial value: 1.0 (100 %)

lrOverrideJerk

LREAL

Factor for the global override of the jerk

  • Value range: 0 ... 1.0
  • Initial value: 1.0 (100 %)

xDisableSWLimit

BOOL

TRUE

Deactivate software end positions.

This input overrides the setting parameterised in the axis (subindex 50) and deactivates the software end position monitoring.

FALSE

The axis setting is effective.

xContinuousUpdate

BOOL

TRUE

Profile parameters are cyclically checked for changes and adopted.

  • Initial value: TRUE

xHalt

BOOL

TRUE

The active movement is cancelled and the axle is brought to a standstill via the half ramp.

  • A change is made to the STOP state.

The deceleration ramp can be cancelled by commanding a new movement (e.g. xMoveVelExecute).

xFinishPositioning

BOOL

TRUE

Interrupted positioning is continued.

  • A positioning process previously interrupted via xAbort is completed.
  • Distances already travelled for relative positioning are taken into account.
  • Cancellation and termination of positioning

xMoveVelExecute

BOOL

TRUE

Start endless travel at a defined speed (MoveVelocity).

  • Endless travel at a defined speed

xMoveAbsExecute

BOOL

TRUE

Start absolute positioning (MoveAbsolute).

  • Absolute positioning

xMoveRelExecute

BOOL

TRUE

Start relative positioning (MoveRelative).

  • Relative positioning

lrPos_Dist

LREAL

Absolute positioning

Absolute target position in relation to the zero position of the axis.

  • Unit: units
  • Initial value: 0

Relative positioning

Distance to be travelled in relation to the target position at the start time of the command.

  • Unit: units
  • Initial value: 0

xHomeAbsSwitch

BOOL

TRUE

Connection for reference switch

For homing modes with a reference switch, connect this input to the digital signal that reflects the status of the reference switch.

xHWLimitPos

BOOL

Positive hardware limit switch

Connect this input to the corresponding digital input to which the limit switch is connected.

TRUE

The positive hardware limit switch has been reached or approached.

  • The structure output xHwLimitSwitchPos is also set to TRUE.
  • The axis is brought to a standstill with the deceleration of the QSP Application.
  • The status changes to "ERROR" with the error message "HWLimitPos"(eErrorID= 20500).

xHWLimitNeg

BOOL

Negative hardware limit switch

Connect this input to the corresponding digital input to which the limit switch is connected.

TRUE

The negative hardware limit switch has been reached or approached.

  • The structure output xHwLimitSwitchNeg is also set to TRUE.
  • The axis is brought to a standstill with the deceleration of the QSP Application.
  • The status changes to "ERROR" with the error message "HWLimitNeg"(eErrorID= 20501).