L_TC2P_scStatusCoordinatedMotion
|
|
|
|
L_TC2P_StatusCoordinatedMotion |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
L_TC2P_scStatusCoordinatedMotion |
– |
|
scStatusCoordinatedMotion |
xFunBusy |
|
– |
BOOL |
|
|
|
|
|
xFunDone |
|
– |
BOOL |
|
|
|
|
|
xFunCommandAborted |
|
– |
BOOL |
|
|
|
|
|
xGroupHaltBusy |
|
– |
BOOL |
|
|
|
|
|
xGroupHaltDone |
|
– |
BOOL |
|
|
|
|
|
xHWLimitSwitchANY |
|
– |
BOOL |
|
|
|
|
|
xSWLimitEnabledALL |
|
– |
BOOL |
|
|
|
|
|
xSWLimitSwitchANY |
|
– |
BOOL |
|
|
|
|
|
eKinematicType |
|
– |
L_MC4P_KinematicType |
|
|
|
|
|
eAxesGroupState |
|
– |
L_MC4P_AxesGroup_State |
|
|
|
|
|
xAxesGroupWarning |
|
– |
BOOL |
|
|
|
|
|
xAxesGroupError |
|
– |
BOOL |
|
|
|
|
|
eAxesGroupErrorID |
|
– |
L_IE1P_Error |
|
|
|
|
|
xInPosition |
|
– |
BOOL |
|
|
|
|
|
|
|
|
|
|
Identifier Data type |
Description of the |
|
|---|---|---|
|
xFunBusy BOOL |
TRUE |
Processing of the activated function is running. The DC link voltage is present. |
|
xFunDone BOOL |
TRUE |
Processing of the activated function successfully completed. |
|
xFunCommandAborted BOOL |
TRUE |
The activated function was cancelled by another function module. |
|
xGroupHaltBusy BOOL |
TRUE |
The xGroupHalt function is executed |
|
xGroupHaltDone BOOL |
TRUE |
The axes have come to a standstill on the track via the xGroupHalt function |
|
xHWLimitSwitchANY BOOL |
TRUE |
A hardware limit switch has triggered on one of the axes in the axis group. For details, see ascStatusBasicMotion. |
|
xSWLimitEnabledALL BOOL |
TRUE |
Monitoring of the software end positions is activated for all axes in the axis group. |
|
xSWLimitSwitchANY BOOL |
TRUE |
A software end position was exceeded for one of the axles in the axle group. For details, see ascStatusBasicMotion. |
|
eKinematicType L_MC4P_KinematicType |
|
|
|
eAxesGroupState L_MC4P_AxesGroup_State |
Current axle group status. |
|
|
1 |
GroupErrorStop |
|
|
2 |
GroupDisabled |
|
|
3 |
GroupStandby |
|
|
4 |
GroupStopping |
|
|
5 |
GroupMoving |
|
|
6 |
GroupHoming |
|
|
xAxesGroupWarning BOOL |
TRUE |
There is a warning in the axle group. |
|
xAxesGroupError BOOL |
TRUE |
There is an error in the axle group. |
|
eAxesGroupErrorID L_IE1P_Error |
If xAxesGroupError= TRUE: Error number for the error that has occurred. Reference manual "FAST technology modules": Here you will find information on error or warning messages. |
|
|
xInPosition BOOL |
TRUE |
The target position has been reached. |