L_TC2P_scStatusCoordinatedMotion

 

 

 

L_TC2P_StatusCoordinatedMotion

 

 

 

 

 

 

 

 

 

 

 

L_TC2P_scStatusCoordinatedMotion

–

 

scStatusCoordinatedMotion

xFunBusy

 

–

BOOL

 

 

 

 

xFunDone

 

–

BOOL

 

 

 

 

xFunCommandAborted

 

–

BOOL

 

 

 

 

xGroupHaltBusy

 

–

BOOL

 

 

 

 

xGroupHaltDone

 

–

BOOL

 

 

 

 

xHWLimitSwitchANY

 

–

BOOL

 

 

 

 

xSWLimitEnabledALL

 

–

BOOL

 

 

 

 

xSWLimitSwitchANY

 

–

BOOL

 

 

 

 

eKinematicType

 

–

L_MC4P_KinematicType

 

 

 

 

eAxesGroupState

 

–

L_MC4P_AxesGroup_State

 

 

 

 

xAxesGroupWarning

 

–

BOOL

 

 

 

 

xAxesGroupError

 

–

BOOL

 

 

 

 

eAxesGroupErrorID

 

–

L_IE1P_Error

 

 

 

 

xInPosition

 

–

BOOL

 

 

 

 

 

 

 

 

Identifier

Data type

Description of the

xFunBusy

BOOL

TRUE

Processing of the activated function is running.

The DC link voltage is present.

xFunDone

BOOL

TRUE

Processing of the activated function successfully completed.

xFunCommandAborted

BOOL

TRUE

The activated function was cancelled by another function module.

xGroupHaltBusy

BOOL

TRUE

The xGroupHalt function is executed

xGroupHaltDone

BOOL

TRUE

The axes have come to a standstill on the track via the xGroupHalt function

xHWLimitSwitchANY

BOOL

TRUE

A hardware limit switch has triggered on one of the axes in the axis group. For details, see ascStatusBasicMotion.

xSWLimitEnabledALL

BOOL

TRUE

Monitoring of the software end positions is activated for all axes in the axis group.

xSWLimitSwitchANY

BOOL

TRUE

A software end position was exceeded for one of the axles in the axle group.

For details, see ascStatusBasicMotion.

eKinematicType

L_MC4P_KinematicType

  • L_MC4P_RoboticHandling, L_MK4P_RoboticKinematics for coord. Multi-axis

eAxesGroupState

L_MC4P_AxesGroup_State

Current axle group status.

1

GroupErrorStop

2

GroupDisabled

3

GroupStandby

4

GroupStopping

5

GroupMoving

6

GroupHoming

xAxesGroupWarning

BOOL

TRUE

There is a warning in the axle group.

xAxesGroupError

BOOL

TRUE

There is an error in the axle group.

eAxesGroupErrorID

L_IE1P_Error

If xAxesGroupError= TRUE: Error number for the error that has occurred.

Reference manual "FAST technology modules":

Here you will find information on error or warning messages.

xInPosition

BOOL

TRUE

The target position has been reached.