L_TB2P_scStatusBasicMotionExtended
|
L_TB2P_scStatusBasicMotionExtended |
|||||||
|---|---|---|---|---|---|---|---|
|
L_TB2P_scStatusBasicMotionExtended |
- |
scStatusBasicMotion |
xReadyForOperation |
- |
BOOL |
||
|
xOperationEnabled |
- |
BOOL |
|||||
|
xReadyForMotion |
- |
BOOL |
|||||
|
eAxisErrorID |
- |
L_IE1P_Error |
|||||
|
xSTOActive |
- |
BOOL |
|||||
|
xQSPActive |
- |
BOOL |
|||||
|
xAbortBusy |
- |
BOOL |
|||||
|
xAbortDone |
- |
BOOL |
|||||
|
xJoggingBusy |
- |
BOOL |
|||||
|
xHomingBusy |
- |
BOOL |
|||||
|
xHomingDone |
- |
BOOL |
|||||
|
xIsHomed |
- |
BOOL |
|||||
|
lrActVel |
- |
LREAL |
|||||
|
lrSetVelOut |
- |
LREAL |
|||||
|
lrActPos |
- |
LREAL |
|||||
|
lrSetPosOut |
- |
LREAL |
|||||
|
lrActFollowingError |
- |
LREAL |
|||||
|
xFunBusy |
- |
BOOL |
|||||
|
xFunDone |
- |
BOOL |
|||||
|
xFunCommandAborted |
- |
BOOL |
|||||
|
xHaltBusy |
- |
BOOL |
|||||
|
xHaltDone |
- |
BOOL |
|||||
|
eControlMode |
- |
L_MC1P_ControlMode |
|||||
|
xHwLimitSwitchNeg |
- |
BOOL |
|||||
|
xHwLimitSwitchPos |
- |
BOOL |
|||||
|
xSwLimitEnabled |
- |
BOOL |
|||||
|
xSwLimitSwitchNeg |
- |
BOOL |
|||||
|
xSwLimitSwitchPos |
- |
BOOL |
|||||
|
eAxisType |
- |
L_MC1P_DriveType |
|||||
|
eAxisState |
- |
L_MC1P_AXIS_STATE |
|||||
|
xAxisWarning |
- |
BOOL |
|||||
|
xAxisError |
- |
BOOL |
|||||
|
xDriveWarning |
- |
BOOL |
|||||
|
xDriveError |
- |
BOOL |
|||||
|
dwDriveErrorID |
- |
DWORD |
|||||
|
xConstantVelocity |
- |
BOOL |
|||||
|
xAccelerating |
- |
BOOL |
|||||
|
xDecelerating |
- |
BOOL |
|||||
|
Identifier Data type |
Description of the |
|
|---|---|---|
|
xReadyForOperation BOOL |
The axle is faultless. The DC link voltage is present. "Safe Torque Off" (STO) is not active. |
|
|
xOperationEnabled BOOL |
The axle is released. The brake is released. |
|
|
xReadyForMotion BOOL |
The axle is approved and fault-free. The brake is released. |
|
|
xError BOOL |
TRUE |
There is an error in the technology module. |
|
xWarning BOOL |
TRUE |
There is a warning in the technology module. |
|
eErrorID L_IE1P_ErrorL |
ID of the error or warning message if xError= TRUE or xWarning= TRUE. Here you will find information on error or warning messages:
|
|
|
xSTOActive BOOL |
TRUE |
A "Safe Torque Off" (STO) has been triggered and is active. The axis is torque-free and the controller is locked. |
|
xQSPActive BOOL |
TRUE |
The xQSPApplication input was set to TRUE. The technology module is in the STOP state, the axis is brought to a standstill. The output is reset as soon as the axis is at a standstill. |
|
xAbortBusy BOOL |
TRUE |
The activated function is cancelled by the xAbort input. |
|
xAbortDone BOOL |
TRUE |
The activated function was cancelled by the xAbort input. |
|
xJoggingBusy BOOL |
TRUE |
The manual drive function is active. The technology module is in the JOGGING state. |
|
xHomingBusy BOOL |
TRUE |
The reference run is executed. The technology module is in the HOMING state. |
|
xHomingDone BOOL |
TRUE |
The reference run was successfully completed. |
|
xIsHomed BOOL |
TRUE |
The axis is referenced ("reference known"). xIsHomed may only be analysed when the xAxisAvailable status is reported. |
|
eTMState L_TB2P_States |
Current status of the technology module
|
|
|
scStatusBasicMotion L_TB2P_scStatusBasicMotion |
Structure of the status data of the function module
|
|
|
lrActVel LREAL |
Current speed
|
|
|
lrSetVelOut LREAL |
Target speed
|
|
|
lrActPos LREAL |
Current position
|
|
|
lrSetPosOut LREAL |
Target position
|
|
|
lrActFollowingError LREAL |
Current following distance
|
|
|
xFunBusy BOOL |
TRUE |
Processing of the activated function is running. The DC link voltage is present. |
|
xFunDone BOOL |
TRUE |
Processing of the activated function successfully completed. |
|
xFunCommandAborted BOOL |
TRUE |
The activated function was cancelled by another function module. |
|
xHaltBusy BOOL |
TRUE |
The stop function is executed |
|
xHaltDone BOOL |
TRUE |
The stop function has been successfully completed. |
|
eControlMode L_MC1P_ControlMode |
Current control mode of the axis |
|
|
xHwLimitSwitchNeg BOOL |
TRUE |
Negative hardware limit switch exceeded. |
|
xHwLimitSwitchPos BOOL |
TRUE |
Positive hardware limit switch exceeded. |
|
xSwLimitEnabled BOOL |
TRUE |
Monitoring of the software end positions is activated. |
|
xSwLimitSwitchNeg BOOL |
TRUE |
Negative software end position exceeded. |
|
xSwLimitSwitchPos BOOL |
TRUE |
Positive software end position exceeded. |
|
eAxisType L_MC1P_DriveType |
Connected axle type |
|
|
eAxisState L_MC1P_AXIS_STATE |
Current PLCopen status of the axis |
|
|
xAxisWarning BOOL |
TRUE |
There is a warning in the axis data or a connected function block. |
|
xAxisError BOOL |
TRUE |
The output is TRUE for :
|
|
xDriveWarning BOOL |
TRUE |
There is a warning in the inverter. |
|
xDriveError BOOL |
TRUE |
There is a fault in the inverter. |
|
dwDriveErrorID DWORD |
TRUE |
If xDriveError= TRUE or xDriveWarnin= TRUE: Error number for the error that has occurred in the inverter. |
|
xConstantVelocity BOOL |
TRUE |
The specified speed was reached for the first time. |
|
xAccelerating BOOL |
TRUE |
The axle is accelerated. (Amount of increase in speed) |
|
xDecelerating BOOL |
TRUE |
The axle is decelerated or braked. (Amount of reduction in speed) |
|
xDirectionPositive BOOL |
TRUE |
The axis moves in a positive direction. |
|
xDirectionNegative BOOL |
TRUE |
The axis moves in a negative direction. |
|
xInPosition BOOL |
TRUE |
The target position has been reached. |
|
xAxisAvailable BOOL |
TRUE |
The axis can be used in the application, i.e. initialisation has been completed without errors. Valid actual values are available and communication to the lower-level drive is available. |
|
xStandstillSetVelocity BOOL |
TRUE |
The set speed of the axis is zero. |
|
xStandstillActVelocity BOOL |
TRUE |
The actual speed is within the defined window (window standstill, subindex 132) |