i9x0.AccountManagementGuidelines
The Account Management Guidelines of the i9x0 servo inverter are described below. The focus here is on i9x0.UserManagement and the SSH / SFTP access.
i9x0.AccountManagementGuidelines :: i9x0.UserManagement
Default / Factory Settings:
The User Management of the i9x0 servo inverter is deactivated and must be activated via the PLC Designer. If this is done, the following accounts are automatically created by default:
-
<name> (user) | "Administrator" (group) | <password> (password)
<name> and <password> must be assigned upon activiation of the User Management. -
"Anonymous_OPCUAServer" (user) | "Anonymous_OPCUAServer" (group) |"" (password)
The empty string password is not relevant, as this user is intended exclusively for anonymous use of the OPC UA server, and it is precisely this anonymous use that does not require a password. -
"EngineeringItf" (user) | "Engineering" (group) | DefaultPassword (password)
For reasons of compatibility with older firmware versions, this default user is provided with a default password.
Account Handling:
-
It is recommended to remove the "EngineeringItf" (user), which is included due to compatibility with older firmware versions, when reconfiguring or to individualize its password.
-
New users and groups can be defined using the PLC Designer.
Policies:
The Runtime Password Policy is deactivated by default. It is recommended to activate it and adapt it to the current password strength requirements. Current default settings after activation are:
-
Minimum length = 8
-
Number of unique characters = 4
-
Requires lowercase letter = activated
-
Requires uppercase letter = activated
-
Requires digit = activated
-
Requires special character = activated
-
Must not contain username = activated
Controller.AccountManagementGuidelines :: SFTP
Default / Factory Settings:
By default, no customer keys are present in the delivery state.
Key Handling:
-
The customer can store their own customer key.
Policies:
The customer.pkk customer key has the following requirements:
-
RSA
-
min. 2048 Bits