i9x0.Firewall : PortList with deactive firewall

Port List with deactivated firewall

The following table shows the ports, scanned with nmap -sT (TCP connect scan) without activated i9x0.Firewall.

Open TCP Ports with deactivated i9x0.Firewall

Port

Engineering Port X16

PROFINET Module

X256/X257

Ethernet/IP Module X266/X267

EoE via onboard EtherCAT

X236/X237

Protocol

22/tcp

þopen*1)

ofiltered

ofiltered

þopen*1)

Secure Shell (SSH)

80/tcp

þopen

ofiltered

ofiltered

þopen

Hypertext Transfer Protocol (HTTP)

443/tcp

þopen

þopen

þopen

þopen*3)

Secure Hypertext Transfer Protocol (HTTPS)

1217/tcp

þopen

ofiltered

ofiltered

þopen

PLC-Designer Gateway-Search

4840/tcp

þopen

þopen

þopen

þopen

(OPC UA) OPC Unified Architecture

6000/tcp

þopen*2)

ofiltered

ofiltered

þopen*2)

EtherCAT Master Diagnosis

8080/tcp

þopen*3)

ofiltered

ofiltered

þopen*3)

Web Visu Server (only available for the extended Controller variant)

9410/tcp

þopen

þopen

þopen

þopen

GCI

11740/tcp

þopen

þopen

þopen

þopen

PLC-Designer Gateway

44818/tcp

ofiltered

ofiltered

þopen

ofiltered

EtherNET/IP Messaging’

47877/tcp

þopen*1)

ofiltered

ofiltered

þopen*1)

SFTP (SSH File Transfer Protocol)

*1) For more information, please refer chapter i9x0.SSHServer: Combination of SSH and SFTP via Ports and Networks’

*2) Port 6000/tcp is only open, if the application contains an EtherCAT master object. For example, if 0x4000 is set to ‘CiA 402 [0]’, there is no EtherCAT master object available, and therefore the port 6000/tcp is closed. On the other hand, if 0x4000 is set to ‘TA Table Positioning [20]’ and 0x2371:009 is set to ‘Master [1]’, there is an EtherCAT master object available, and therefore the port 6000/tcp is open.

*3) Port 8080/tcp is only open, if the ‘Extended for customer specific devices only’ variant of i950 is used.

The following table shows the ports, scanned with nmap -sU (UDP scan) without activated i9x0.Firewall.

Open UDP ports with deactivated i9x0.Firewall

Port

Engineering Port X16

PROFINET Module

X256/X257

Ethernet/IP Module

X266/X267

EoE via onboard EtherCAT

X236/X237

Protocol

68/udp

oclosed

oopen|filtered

oopen|filtered

oopen|filtered

DHCP Client

123/udp

oclosed

oopen|filtered

oopen|filtered

oopen|filtered

NTP Client

161/udp

oclosed

þopen

oopen|filtered

oopen|filtered

SNMP Client

1740/udp

1741/udp

1742/udp

1743/udp

þopen|filtered*1)

oopen|filtered*1)

oopen|filtered*1)

þopen|filtered*1)

PLC-Designer UDP Communication

3677/udp

oclosed

oopen|filtered

oopen|filtered

oopen|filtered

ESDCP

*1) Due to the scanning properties of nmap for UDP ports, these udp ports are displayed as ‘open|filtered’. However, UDP communication can only take place via the engineering port and not via PPROFINET or EtherNET/IP.