Save files from online devices
Most Lenze devices offer the option of saving parameter settings in the device in a fail-safe manner.
The situation is different for devices that cannot save parameter settings in a fail-safe manner. This includes the i700 inverter, for example. These devices rely on a higher-level controller to take over this task.
Prerequisite
-
A PLC boot project must (sensibly) be available on the controller.
-
One of the following communication paths must be established to save files:
-
Ethernet W Ethernet to the Lenze Controller
-
Ethernet W CAN via Lenze controller
-
Ethernet W EtherCAT via Lenze controller
-
A greyed-out button
is a visible sign that it is not possible to save files. For example, if the i700 inverter is connected via the "Ethernet W EtherCAT via Lenze Controller" communication path.