Configure communication channel

In a communication channel, you define the connection to a PLC and the variables to be exchanged with this controller. The data exchange with a Lenze controller always takes place via the OPC UA protocol. When creating a new EASY UI Designer project via the project configurator, a communication channel for OPC UA is therefore already preconfigured.

How to modify a communication channel or change the communication settings:

  1. Expand the project explorer node Variables.

  2. Select the Channels node below.

    Once you select the channel in the project explorer, the properties pages window displays the channel parameters. You can use these parameters to configure the communication channel.

  3. Make sure that the OPC server Lenze OPCUA is selected in the OPC server/driverfield. The default entry opc.tcp://127.0.0.1:4855 is specified as the URL, which refers to the localhost at port 4855. If the visualisation project and the PLC project are located on the same controller, you can keep this setting unchanged. If you want to establish external communication with a device, the local IP address needs to be replaced by the IP address of the target device and port 4840 must be used.

  4. Confirm your configuration with the OK button.