Changing the cam
Notice
Kennzeichnet Sachgefahren. Wird dieser Hinweis nicht beachtet, kann es zu Sachschäden kommen.
During the travel process of a cam, the interpolation points within the structure must not be changed.
The cam data, basic conditions, or interpolation points are not copied internally, but are directly used for motion control by the technology module. Changing the data has a direct impact on the currently active cam.
The adaptation of the cam during operation via the CamTable1 input is only effective if the slave axis has reached the cam end ( xEndOfProfile output = TRUE).
The cam end is the end point of the cam at which the y-side end point ends in the representation. This ensures that the cam is always switched over at the y-side cam end, even when there is an x offset.
A plausibility check as to whether the cams are fitting together is not carried out and must be ensured by the user.
An immediate cam change can be forced by setting the xCamChangeInstant input to TRUE. When a changeover is active, the data of the new cam are accepted immediately. A new coupling process does not take place.