Dynamic displacement of the cams

The lrReactTimeOn and lrReactTimeOff inputs can be used to set a time shift of the switch-on and switch-off positions for the cams in order to compensate for delay times of connected switching elements, for example.

  • A positive time duration causes the cam to switch earlier, while a negative time duration causes it to switch later.
  • With travel-time cams, the switch-on position is only shifted in time via lrReactTimeOn and the default lrReactTimeOff has no effect.
  • The cam dynamisation (shift of the switch-on position or switch-off position) is limited by 100 times the cycle length. When the limitation is active, the switching output selected via eDigitalOutputSel (default: FB output xSwitch ) is set to TRUE and the limitation is displayed via the "DynamisationError" error (no. 22065). The cam dynamisation (position) is calculated from the current speed multiplied by the time that can be specified via the lrReactTimeOff or lrReactTimeOn input. The error is set if the calculated position is greater than 100 times the cycle length.
Examples:

Setting the shift of the switch-on position

Setting the shift of the switch-off position