Switching performance for position-time tappets
|
Note!
The byTappetNo output is not designed for overlapping tappets and thus must not be projected. Overlapping switch-on states of successive tappets may also occur if the operating time of the position-time tappets is longer than the interval to the switch-on position of the following position-time tappet (post-trigger function). This state must be avoided. If the operating time of a position-based tappet is longer than the total cycle time, the switching output selected via eDigitalOutputSel (default: FB output xSwitch ) is permanently set to TRUE. |
Position/time-based tappet in positive effective direction (PositiveTime)
If the axis position reaches the tappet switch-on position in positive effective direction, the switching output (default: FB output xSwitch ) selected via eDigitalOutputSel is set to TRUE and only reset to FALSE when the defined time has elapsed.
Once the switching output is set to TRUE, a following change in direction has no impact on the cam signal.
|
Example: Position-time cams in positive effective direction
Position/time-based tappet in negative effective direction (NegativeTime)
If the axis position reaches the tappet switch-on position in negative effective direction, the switching output (default: FB output xSwitch ) selected via eDigitalOutputSel is set to TRUE and only reset to FALSE when the defined time has elapsed.
Once the switching output is set to TRUE, a following change in direction has no impact on the cam signal.
|
Example: Position-time cams in negative effective direction