Switching performance for position tappets
Position-based tappet in positive effective direction (PositiveWay)
If the axis position reaches the tappet switch-on position in positive effective direction, the switching output selected via eDigitalOutputSel (default: FB output xSwitch ) is set to TRUE and reset to FALSE if the switch-off position is exceeded.
If a change in direction is effected after the switch-on position has been reached, the switching output is reset to FALSE immediately.
|
Example: Position tappets in positive effective direction
Position-based tappet in negative effective direction (NegativeWay)
If the axis position reaches the tappet switch-on position in negative effective direction, the switching output selected via eDigitalOutputSel (default: FB output xSwitch ) is set to TRUE and reset to FALSE if the switch-off position is exceeded.
If a change in direction is effected after the switch-on position has been reached, the switching output is reset to FALSE immediately.
|
Example: Position tappets in negative effective direction
Position-based tappet in bidirectional effective direction (BidirectionalWay)
If the axis position is within the tappet switch-on and switch-off position, the switching output (default: FB output xSwitch ) selected via eDigitalOutputSel is set to TRUE, irrespective of the process flow direction.
|
Example: Position-based tappets in bidirectional effective direction