L_MK1P_GantryManualControl
This FB can be used for the diagnosis and commissioning of single-axis kinematics.
The FB provides functions for
-
Error reset
-
Activation of manual alignment (in coupling mode "absolute position")
-
Activating the service mode of the kinematic and jogging the single axes separately.
-
Connecting hardware signals of the following axis
-
The display of status signals of the main and following axis as well as the single-axis kinematics
|
|
|
|
L_MK1P_GantryManualControl |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
L_MK1P_Gantry_int |
- |
|
Kinematic |
xInternalControlActive |
|
- |
BOOL |
|
BOOL |
- |
|
xEnableServiceMode |
eKinType |
|
- |
L_MK1P_KinematicType |
|
BOOL |
- |
|
xResetError |
eKinState |
|
- |
L_MK1P_KinematicState |
|
BOOL |
- |
|
xExecuteSyncIn |
eActCouplingMode |
|
- |
L_MK1P_KinCouplingMode |
|
L_MC1P_ControlAxis |
- |
|
scControlMainAxis |
scStatusMainAxis |
|
- |
L_MC1P_StatusAxis |
|
L_MC1P_ControlAxis |
- |
|
scControlFollowingAxis |
scStatusFollowingAxis |
|
- |
L_MCIP_StatusAxis |
|
L_MC1P_HardwareInputs |
- |
|
scHWInputsFollowingAxis |
xServiceModeActive |
|
- |
BOOL |
|
|
|
|
|
xReadyforMotion |
|
- |
BOOL |
|
|
|
|
|
xKinWarning |
|
- |
BOOL |
|
|
|
xKinError |
|
- |
BOOL |
||
|
|
|
eKinErrorID |
|
- |
L_IEIP_Error |
||
|
|
|
xKinHomed |
|
- |
BOOL |
||
|
|
|
xSyncronized |
|
- |
BOOL |
||
|
|
|
xSyncInBusy |
|
- |
BOOL |
||
|
|
|
xWaitForSyncIn |
|
- |
BOOL |
||
|
|
|
xInsidePosWindow |
|
- |
BOOL |
||
|
lrActSkewness |
|
- |
LREAL |
||||
|
lrActTension |
|
- |
LREAL |
||||
VAR_IN_OUT
|
Identifier Data type |
Description |
|
|---|---|---|
|
Kinematic L_MK1P_Gantry_int |
Connection of the gantry instance |
|
inputs
|
Name Data type |
Info/setting options |
|
|---|---|---|
|
xEnableServiceMode BOOL |
TRUE: Activate service mode
|
|
|
xResetError BOOL |
FALSE ä TRUE Reset error of kinematics, main and following axis |
|
|
xExecuteSyncIn BOOL |
FALSE ä TRUE Activate manual alignment, i.e. the following axis is positioned to the set position of the main axis
|
|
|
scControlMainAxis L_MC1P_ControlAxis |
Structure with control information of the main axis
|
|
|
scControlFollowingAxis L_MC1P_ControlAxis |
Structure with control information of the following axis
|
|
|
scHWInputs L_MC1P_HardwareInputs |
Connection of HW signals of the following axis:
The HW signals of the main axis are linked via the TM. |
|
Outputs
|
Name Data type |
Value/meaning |
|
|---|---|---|
|
xInternalControlActive BOOL |
TRUE: Control of the FB via the visualization is activated |
|
|
eKinType L_MK1P_KinematicType |
Type of kinematic |
|
|
eKinState L_MK1P_KinematicState |
State of the kinematic |
|
|
eActCouplingMode L_MK1P_KinCouplingMode |
Actual coupling mode |
|
|
scStatusMainAxis L_MC1P_StatusAxis |
Detailed status information of the main axis |
|
|
scStatusFollowingAxis L_MC1P_StatusAxis |
Detailed status information of the minor axis |
|
|
xServiceModeActive BOOL |
TRUE: Seervice mode is activated. The axes can be enabled and moved separately from each other |
|
|
xReadyforMotion BOOL |
TRUE: The kinematic is in the Synchronized state and can be moved via the main axis. |
|
|
xKinWarning BOOL |
TRUE: Warning active in the kinematic |
|
|
xKinError BOOL |
TRUE: Error in the kinematic active |
|
|
eKinErrorID L_IE1P_Error |
Error number of the currently pending error or warning |
|
|
xKinHomed BOOL |
TRUE: Both axes of the kinematic are referenced |
|
|
xSynchronized BOOL |
TRUE: The axes are aligned. |
|
|
xSyncInBusy BOOL |
TRUE: Alignment is active. |
|
|
xWaitForSyncIn BOOL |
TRUE: The gantry kinematic is waiting for manual alignment. |
|
|
xInsidePosWindwow BOOL |
TRUE: The position of the main and secondary axes are within the parameterized position window in "Absolute position" coupling mode. With a coupling mode <> absolute position, xInsidePosWindow is always TRUE. |
|
|
lrActSkewness LREAL |
Actual skewness of the two axes in relation to each other. - If both axes are referenced, the difference between the two actual positions is displayed. - If at least one of the two axes is not referenced, the position difference is latched once when the two axes are enabled and calculated as an offset. The offset is updated each time the controller is enabled again. |
|
|
lrActTension LREAL |
Actual tension |
|
Commissioning and diagnostics using GantryManualControl
The FB L_MK1P_GantryManualControl can be used for commissioning and diagnostics of the gantry axis.
a) Service mode
-
Once the axes are coupled in the gantry axis, the axes can only be moved separately from each other in service mode. This can be set using the FB L_MK1P_GantryManualControl by activating xEnableServiceMode. The function block can then be used to jog the main and following axis. In the visualization, the control of the respective axis can be accessed via scControlMainAxis and scControlFollowingAxis.
b) Manual alignment of the axes
-
The FB can be used to manually align the gantry axis. The controller must be enabled for this if coupling is present. The kinematic is in the WaitForSyncIn state. The axes can then be manually aligned using xExecuteSyncIn.
c) Diagnostics
-
The status of the gantry axis and possible errors are displayed
-
The current position and speed as well as the most important states and status messages are displayed at a glance for the main and slave axes (as soon as they are connected to the gantry)