Profile switch-over

You can switch over to individual parameters or compete profile data sets during operation. Changes become effective immediately. Several profile data sets are available for switch-over in the following example.

Example

Speed operation is enabled and switch over between profiles 1, 2 and 3 in succession.

No

wProfile
Number

wActive
Profile

eTMState

INFO

A

1

1

STANDBY ➞ MOVEVEL

The axis accelerates with limited jerk to the setpoint speed 100 units/s set in profile 1 and holds this.

B

2

2

MOVEVEL

The axis accelerates with limited jerk to the setpoint speed 200 units/s set in profile 2 and holds this.

C

3

3

MOVEVEL

The axis decelerates with limited jerk to the setpoint speed 50 units/s set in profile 3 and holds this.

D

0

0

MOVEVEL ➞ STANDBY

The axis decelerates to a standstill.