Profile switch-over
You can switch over to individual parameters or compete profile data sets during operation. Changes become effective immediately. Several profile data sets are available for switch-over in the following example.
Speed operation is enabled and switch over between profiles 1, 2 and 3 in succession.
|
No |
wProfile
|
wActive
|
eTMState |
INFO |
|---|---|---|---|---|
|
A |
1 |
1 |
STANDBY ➞ MOVEVEL |
The axis accelerates with limited jerk to the setpoint speed 100 units/s set in profile 1 and holds this. |
|
B |
2 |
2 |
MOVEVEL |
The axis accelerates with limited jerk to the setpoint speed 200 units/s set in profile 2 and holds this. |
|
C |
3 |
3 |
MOVEVEL |
The axis decelerates with limited jerk to the setpoint speed 50 units/s set in profile 3 and holds this. |
|
D |
0 |
0 |
MOVEVEL ➞ STANDBY |
The axis decelerates to a standstill. |