Starting and stopping speed operation

Condition

  • The technology module is in a fault-free state

  • The drive is released ( xReadyForMotion = TRUE)

Type

xSpeedControl = TRUE must be set to start a movement with a defined speed. The finite state machine changes to the MOVEVEL state and the axis accelerated with limited jerk ( lrJerk ) with the preselected acceleration lrAcceleration up to the setpoint speed specified at the lrSetVel input of the technology module. As soon as the setpoint speed is reached, the xConstantVelocity output of the scStatusBasicMotion output structure is set to TRUE. The speed is maintained up to xSpeedControl = FALSE. The axis is brought to a standstill according to the deceleration lrDeceleration and the finite state machine then changes to the STANDBY state.

Alternatively, the axis can also be stopped via xHalt, xAbort or xQSPApplication .

No

xSpeedCtrl

xHalt

xSpeedCtrlBusy

xAbortBusy

xAbortDone

xHaltBusy

xHaltDone

eTMState

INFO

A

FALSE ä TRUE

FALSE

FALSE ä TRUE

FALSE

FALSE

FALSE

FALSE

STANDBY ➞ MOVEVEL

The axis accelerates with limited jerk up to the preselected setpoint speed and holds this.

B

TRUE æ FALSE

FALSE

TRUE æ FALSE

FALSE ä

TRUE æ FALSE

(xAbortDone)

FALSE ä TRUE (for one cycle)

FALSE

FALSE

MOVEVEL ➞

STOP

The axis decelerates to a standstill with the deceleration set in the active profile.

C

FALSE ä TRUE

FALSE

FALSE ä TRUE

FALSE

FALSE

FALSE

FALSE

STANDBY

➞

MOVEVEL

The axis accelerates with limited jerk up to the preselected setpoint speed and holds this.

D

TRUE

FALSE ä TRUE

TRUE æ FALSE

FALSE

FALSE

FALSE ä

TRUE æ FALSE

(xHaltDone)

FALSE ä TRUE

MOVEVEL

STOP

The axis decelerates to a standstill with the deceleration set for the holding function.

E

TRUE

TRUE æ FALSE

FALSE ä TRUE

FALSE

FALSE

FALSE

TRUE æ FALSE

STOP ➞

MOVEVEL

The axis accelerates with limited jerk up to the preselected setpoint speed and holds this.

F

TRUE æ FALSE

FALSE

TRUE æ FALSE

FALSE ä

TRUE æ FALSE

(xAbortDone)

FALSE ä TRUE (for one cycle)

FALSE

FALSE

MOVEVEL

STOP

The axis decelerates to a standstill with the deceleration set in the active profile.