Starting and stopping speed operation
-
The technology module is in a fault-free state
-
The drive is released ( xReadyForMotion = TRUE)
xSpeedControl = TRUE must be set to start a movement with a defined speed. The finite state machine changes to the MOVEVEL state and the axis accelerated with limited jerk ( lrJerk ) with the preselected acceleration lrAcceleration up to the setpoint speed specified at the lrSetVel input of the technology module. As soon as the setpoint speed is reached, the xConstantVelocity output of the scStatusBasicMotion output structure is set to TRUE. The speed is maintained up to xSpeedControl = FALSE. The axis is brought to a standstill according to the deceleration lrDeceleration and the finite state machine then changes to the STANDBY state.
Alternatively, the axis can also be stopped via xHalt, xAbort or xQSPApplication .
|
No |
xSpeedCtrl |
xHalt |
xSpeedCtrlBusy |
xAbortBusy |
xAbortDone |
xHaltBusy |
xHaltDone |
eTMState |
INFO |
|---|---|---|---|---|---|---|---|---|---|
|
A |
FALSE ä TRUE |
FALSE |
FALSE ä TRUE |
FALSE |
FALSE |
FALSE |
FALSE |
STANDBY ➞ MOVEVEL |
The axis accelerates with limited jerk up to the preselected setpoint speed and holds this. |
|
B |
TRUE æ FALSE |
FALSE |
TRUE æ FALSE |
FALSE ä TRUE æ FALSE (xAbortDone) |
FALSE ä TRUE (for one cycle) |
FALSE |
FALSE |
MOVEVEL ➞ STOP |
The axis decelerates to a standstill with the deceleration set in the active profile. |
|
C |
FALSE ä TRUE |
FALSE |
FALSE ä TRUE |
FALSE |
FALSE |
FALSE |
FALSE |
STANDBY ➞ MOVEVEL |
The axis accelerates with limited jerk up to the preselected setpoint speed and holds this. |
|
D |
TRUE |
FALSE ä TRUE |
TRUE æ FALSE |
FALSE |
FALSE |
FALSE ä TRUE æ FALSE (xHaltDone) |
FALSE ä TRUE |
MOVEVEL
STOP |
The axis decelerates to a standstill with the deceleration set for the holding function. |
|
E |
TRUE |
TRUE æ FALSE |
FALSE ä TRUE |
FALSE |
FALSE |
FALSE |
TRUE æ FALSE |
STOP ➞ MOVEVEL |
The axis accelerates with limited jerk up to the preselected setpoint speed and holds this. |
|
F |
TRUE æ FALSE |
FALSE |
TRUE æ FALSE |
FALSE ä TRUE æ FALSE (xAbortDone) |
FALSE ä TRUE (for one cycle) |
FALSE |
FALSE |
MOVEVEL
STOP |
The axis decelerates to a standstill with the deceleration set in the active profile. |