Positioning modes

No.

Positioning mode

Description

0

absolute

The axis travels to an absolute position.

  • The absolute position describes the distance between the zero position and the target position. (absolute position = target position)

  • The home position for the absolute position is the zero position.

  • The home position must be known.

The rotary table positioning is basically an absolute positioning with target positions between 0 and 360 angular degree [°]. In this mode the zero point can also be overtravelled if this is the shortest way to the target position:

1

relative

The axis travels a defined distance.

  • The relative position considers the distance to the starting position.
    (relative position = target position - starting position)

  • The home position for the starting point of the distance is the target position of the travel profile executed previously.

2

velocity

Continuous constant travel/movement

  • This mode does not require a predefined position but follows the profile parameters.
  • Acceleration and deceleration are based on the profile parameters lrAcceleration and lrDeceleration .
  • The travel direction is defined by the sign of the travelling speed (+: CW / -: CCW).

3

absolute CW_modulo

The axis travels to an absolute position in CW direction.

  • Can only be used for Modulo measuring system (rotary table application).

  • The home position for the absolute position is the zero position.

  • The home position must be known.

In CW direction, the zero position of the axis can be overtravelled.

 

If parameter xAbsoluteModuloCycle = TRUE, the following applies:

It can be positioned over distances of several cycle lengths.

  • Target position >= cycle length: The target position is approached in the next cycle (+n).

  • Target position < 0: Not allowed
  • Target position = current target position (there is a movement of one revolution)

4

absolute CCW_modulo

The axis travels to an absolute position in CCW direction.

  • Can only be used for Modulo measuring system (rotary table application).

  • The home position for the absolute position is the zero position.

  • The home position must be known.

In CCW direction, the zero position of the axis can be overtravelled.

 

If parameter xAbsoluteModuloCycle = TRUE, the following applies:

It can be positioned over distances of several cycle lengths.

  • Target positions >= cycle length: Not allowed

  • Target positions < 0: The target position is approached in the previous cycle (-n).

  • The absolute target position in the cycle results from the modulo calculation of the negative target position: Target = -10 => 350 (absolute target position)

  • Target position = current target position (there is a movement of one revolution)

If a valid TP sequence profile has been set in the profile data set (TP Overchange Profile) the touch probe interface is also evaluated.