Parameter set information

Parameter
Address
Name / setting range / [default setting]
Information
0x2114:001
Parameter set: Version
–
Safety parameter (Safety parameter list)
 
Display of the version of the safe parameter set.
Changes can be made via the +Safety parameter list+ dialog.
10405
iSM ES V1.4
10505
iSM ES-SOE V1.5
0x2114:002
Parameter set: Project CRC
0 ... [0] ... 4294967295
Project CRC of the safe parameter set.
0x2115:001
Parameter set: Status
–
Read only
 
Current status of the safe parameter set.
0
No parameter set
1
Valid parameter set
4
CRC error
5
Version error
7
Plausibility error
8
Assignment error
9
Local read error
10
Communication error with basic device
11
Faulty release
12
Different CRCs
13
Changed parameter set
14
Parameter set checked
15
Parameter set check active
0x2115:002
Parameter set: Current CRC
–
Read only
 
Display of the current parameter CRC from the safe parameter set.
0x2115:003
Parameter set: Last valid CRC
–
Read only
 
Display of the last valid parameter set CRC.
0x2115:004
Parameter set: Parameter setting time stamp
–
Read only: x s
 
Time when the parameter set is taken over from the device as the value of the power-on time meter.
0x2115:005
Parameter set: Error information 1
–
Read only
 
Error number in case of a plausibility error (0x2115:001 = 7).
0x2115:006
Parameter set: Error information 2
–
Read only
 
Reserved
0x2115:007
Parameter set: Error information 3
–
Read only
 
0x2115:008
Parameter set: Current CRC without specific identifiers
–
Read only
 
Display of the current parameter CRC from the safe parameter set without taking into account the following device-specific identifiers:
–
Safety address (0xF980:002)
 
–
CIP Safety - Node ID (0x212A:005)
 
–
CIP Safety - SNN Date (0x212A:006)
 
–
CIP Safety - SNN Time (0x212A:007)
 
–
CIP Safety - SCTS Date (0x212A:008)
 
–
CIP Safety - SCTS Time (0x212A:009)
 
This parameter makes it possible to effectively check the consistency of safety function configurations across different devices.