0x213A:001
|
MUT: Mute S-Bus
–
Safety parameter (Safety parameter list)
|
Selection of sources to be hidden.
|
|
0
|
No muting
|
|
|
3
|
Mute completely
|
|
0x213A:002
|
MUT: Mute SD-In1
–
Safety parameter (Safety parameter list)
|
Selection of sources to be hidden.
|
|
0
|
No muting
|
|
|
1
|
Mute
|
|
0x213A:003
|
MUT: Mute SD-In2
–
Safety parameter (Safety parameter list)
|
Selection of sources to be hidden.
|
|
0
|
No muting
|
|
|
1
|
Mute
|
|
0x213A:016
|
MUT: Mute SD-In1-A
–
Safety parameter (Safety parameter list)
|
|
0
|
No muting
|
|
1
|
Mute
|
|
0x213A:017
|
MUT: Mute SD-In1-B
–
Safety parameter (Safety parameter list)
|
|
0
|
No muting
|
|
1
|
Mute
|
|
0x213A:018
|
MUT: Mute SD-In2-A
–
Safety parameter (Safety parameter list)
|
|
0
|
No muting
|
|
1
|
Mute
|
|
0x213A:019
|
MUT: Mute SD-In2-B
–
Safety parameter (Safety parameter list)
|
|
0
|
No muting
|
|
1
|
Mute
|
|
0x213B:001
|
MUT: Password
0 ... [0] ... 4294967295
–
Safety parameter (Safety parameter list)
|
Password to activate the function.
Enter "0" to reset the password.
|
|
0x213B:002
|
MUT: Remaining time
|
Remaining time until the function is automatically terminated.
The function is active for a maximum of 30 minutes.
|
|
0x213C
|
MUT "MUT active" - Output
–
Safety parameter (Safety parameter list)
|
Selection of the safe output for the "MUT active" feedback.
|
|
0
|
Disabled
|
|
|
1
|
SD-Out1 positive logic
|
|
2
|
SD-Out1 negative logic
|