Status messages
Status message via network
This status message is sent via non-secure interfaces. The status message must not be used to control other safety functions!
The inverter status word (0x282A:004) and the CiA status word (0x6041) contain the status of the STO function according to the following truth table. These two parameter objects can be read via non-secure network interfaces.
|
Status
|
Status message
|
||||
|
Safe input / channel
|
Inverter device state
|
Inverter status word
(Object 0x282A:004)
|
CiA status word
(Object 0x6041)
|
||
|
SIA
|
SIB
|
Bit 10
|
Bit 11
|
Bit 15
|
|
|
LOW
|
LOW
|
STO active
|
1
|
1
|
0
|
|
LOW
|
HIGH
|
Inverter disabled (safety)
|
1
|
0
|
0
|
|
HIGH
|
LOW
|
1
|
0
|
0
|
|
|
HIGH
|
HIGH
|
Drive enabled
|
0
|
0
|
1
|
Note: A discrepancy at the SIA and SIB inputs is not diagnosed. A discrepancy exists if bit 10 = 1 and bit 11 = 0 in the inverter status word (0x282A:004).
Status message via digital outputs
This status message is sent via non-secure interfaces. The status message must not be used to control other safety functions!
In 0x2634:xxx you set the function of the digital outputs. By selecting [55], you can output the “Inverter disabled (safety)” status and by selecting [155], you can output the “STO active” status via a non-safe output (e.g. digital output 1).
|
Status
|
Status message
|
|||
|
Safe input / channel
|
Inverter device state
|
Function of digital outputs
0x2634:xxx
|
||
|
SIA
|
SIB
|
"Inverter disabled (safety)" [55]
|
"STO active" [155]
|
|
|
LOW
|
LOW
|
STO active
|
1
|
1
|
|
LOW
|
HIGH
|
Inverter disabled (safety)
|
1
|
0
|
|
HIGH
|
LOW
|
1
|
0
|
|
|
HIGH
|
HIGH
|
Drive enabled
|
0
|
0
|