Status LEDs

Notes on the connection status with IO-Controller can be obtained via the LEDs "BUS RDY" and "BUS ERR" of the PROFINET option (front of the device).
In addition, the LEDs "L/A" at the RJ45 sockets indicate the connection status to the network.
 
"BUS RDY" LED (green)
State
Meaning
Off
Not connected
No connection to the IO-Controller
Blinking (1 Hz)
Connected
IO-Controller in STOP
On
Data exchange
IO-Controller in RUN (DATA_EXCHANGE)
 
"BUS ERR" LED (red)
State
Meaning
Off
No fault
No fault
Blinking (1 Hz)
IO-Device identifies (localises)
The PROFINET function "node flashing test" is triggered by IO-Controller. The flickering LED serves to identify (locate) an accessible IO-Device.
Blinking fast
Impermissible settings
Impermissible settings: Stack, station name or IP parameters are invalid.
On
Fault
Communication error (e. g. Ethernet cable removed)
 
LED "L" (Link, green)
Status
Meaning
Off
Not connected
No connection to the network
On
Connected
A physical connection to the network is available
 
LED "A" (Activity, yellow)
Status
Meaning
On or flickers
Traffic
Data is exchanged via the network