Default mapping

The default mapping for the "Cyclic sync torque mode" is defined in the following parameters:
 
Parameter
Designation
Data type
0x1601
RPDO-->axis: cyclic sync torque mode (cst)
RECORD
0x1A01
Axis-->TPDO: cyclic sync torque mode (cst)
RECORD
 
Data received from the Controller (RPDO)
Parameter
Designation
Data type
0x6040
CiA402 control word
UNSIGNED_16
0x2830
Lenze control word
UNSIGNED_16
0x6060
Operating mode: selection
INTEGER_8
0x60B2
Torque: offset
INTEGER_16
0x6071
Torque: setpoint torque
INTEGER_16
0x2946:1
Speed limitation: upper speed limit
INTEGER_32
0x2946:2
Speed limitation: lower speed limit
INTEGER_32
 
 
Data sent to the Controller (TPDO)
Parameter
Designation
Data type
0x6041
CiA402 status word
UNSIGNED_16
0x2831
Lenze status word
UNSIGNED_16
0x6061
Operating mode: display
INTEGER_8
0x603F
Error code
UNSIGNED_16
0x606C
Velocity: actual velocity
UNSIGNED_16
0x6077
Torque: actual torque
INTEGER_16