Control commands and status information

The following control commands can be executed in the "cyclically synchronous torque" operating mode via the CiA402 control word 0x6040:
 
Control word
State
Function
Bit 4
0
reserved (bit must be set to "0")
Bit 5
0
reserved (bit must be set to "0")
Bit 6
0
reserved (bit must be set to "0")
Bit 8
0
↗
1
Stop
 
The following status information are output via the CiA402 status word 0x6041 in the "cyclic sync torque mode":
 
Status word
State
Meaning
Bit 12
0
"Cyclic sync torque mode" is inactive
1
"Cyclic sync torque mode" is active