Control commands and status information
The following control commands can be executed in the "cyclically synchronous torque" operating mode via the CiA402 control word 0x6040:
|
Control word
|
State
|
Function
|
|
Bit 4
|
0
|
reserved (bit must be set to "0")
|
|
Bit 5
|
0
|
reserved (bit must be set to "0")
|
|
Bit 6
|
0
|
reserved (bit must be set to "0")
|
|
Bit 8
|
0
↗ 1 |
Stop
|
The following status information are output via the CiA402 status word 0x6041 in the "cyclic sync torque mode":
|
Status word
|
State
|
Meaning
|
|
Bit 12
|
0
|
"Cyclic sync torque mode" is inactive
|
|
1
|
"Cyclic sync torque mode" is active
|