Torque limits

Details
The positive and negative torque limit can be set independently of each other. The torque limit must be set to the maximum torque. 0x6072
 
–
Display of the current positive torque limit in 0x2949:004.
 
–
Display of the current negative torque limit in 0x2949:003.
 
The torque limits are also active in the "Velocity Mode" with the "Servo control (SC-ASM)" motor control mode.
Regardless of the setting in 0x2949:004 and 0x2949:004, the maximum torque does not exceed the value configured in 0x6072.
 
 
The setting is made in percent with reference to the rated motor torque set in 0x6076.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x294A:001
Torque limits offset: Torque offset
-3276.7 ... [0.0] ... 3276.7 %
0x294A:002
Torque limits offset: Resulting positive torque limit
–
Read only: x.x %
 
0x294A:003
Torque limits offset: Resulting negative torque limit
–
Read only: x.x %
 
0x60B2
Offset torque
-3276.8 ... [0.0] ... 3276.7 %
Offset torque
–
100 % 
=
 rated motor power (0x6076)
 
0x60E0
Positive torque limit
0.0 ... [100.0] ... 3276.7 %
Positive torque limit source for speed control with torque limitation.
–
100 % = Rated motor torque 0x6076
 
0x60E1
Negative torque limit
0.0 ... [100.0] ... 3276.7 %
Negative torque limit source for speed control with torque limitation.
–
100 % = Rated motor torque 0x6076