Following error detection and in-position detection
The "following error detection" and "in-position detection" are functions of the position control. All parameters correspond to the CiA 402 specification.
Input data
|
Parameter
|
Name
|
Data type
|
|
Set position
|
INTEGER_32
|
|
|
Position demand internal value
|
INTEGER_32
|
|
|
Internal set position
|
INTEGER_32
|
|
|
Following error window
|
UNSDIGNED_32
|
|
|
Following error delay
|
UNSIGNED_16
|
|
|
Position reached window
|
UNSIGNED_32
|
|
|
Position reached delay
|
UNSIGNED_16
|
Output data
|
Parameter
|
Name
|
Data type
|
|
Internal actual position
|
INTEGER_32
|
|
|
Actual position
|
INTEGER_32
|
|
|
Following error actual value
|
INTEGER_32
|
|
|
Control effort
|
INTEGER_32
|
|
|
CiA status word
|
UNSIGNED_16
|
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x6065
|
Following error window
0 ... [1000] ... 4294967295
|
Setting of the symmetrical tolerance window around the setpoint position for following error detection.
–
0 = following error detection deactivated.
–
> 0 = following error detection activated.
–
A following error is detected if the actual position is outside this tolerance window.
–
If the following error is detected longer than the time defined in 0x6066 in [ms], bit 13 ("following error") is set in the CiA status word (0x6041).
–
0x60F4 displays the current deviation of the actual position from the setpoint position.
|
|
|
0x6066
|
Following error delay
0 ... [0] ... 0 ms
|
Setting of time delay for the following error detection.
0 = the following error is evaluated without a time delay.
|
|
|
0x6067
|
Position reached window
0 ... [1000] ... 4294967295
|
Setting of the symmetrical tolerance window around the target position (0x607A) for the target position detection.
|
|
|
0x6068
|
Position reached delay
0 ... [0] ... 0 ms
|
Setting of time monitoring for the target position detection.
0 = the position in the target window is evaluated without a time delay.
|
|