SSI encoder
SSI absolute value encoder (Synchronous Serial Interface) generate the angle information by optically scanning a code disc (e.g. as Gray Code). Each (absolute) angular position of the encoder corresponds to a code pattern that can be uniquely assigned.
All encoders that use the Stegmann SSI protocol are supported:
–
Supported bit rates for SSI communication: 150 ... 1000 kbits
–
Supported data word widths: 1 ... 31 bits (effective)
–
Supported output code of the SSI encoder: Gray or Binary
–
Cycle time: 62.5
µ
s, 125 µ
s and 250 µ
s . –
Encoder supply: U < 12 V, I
≤
0.25 AHow to parameterise the SSI encoder:
1.
Set the supply voltage of the SSI encoder used in 0x2C42:002.
2.
Set selection "5: SSI encoder" as the encoder type in 0x2C40.
3.
Set the transmission rate for SSI communication in 0x2C4A:001.
With the SSI protocol, the permissible transmission rate decreases as the cable lengths increase. A safe transmission rate must be set according to the length of the encoder cable used and the electromagnetic interference level.
4.
Set the telegram length in 0x2C4A:002.
The telegram length reflects the number of data bits used for transmission of a complete SSI data packet.
The telegram length reflects the number of data bits used for transmission of a complete SSI data packet.
5.
Break the received SSI data word down into partwords and, if necessary, activate data conversion of Gray into binary code.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2C4A:001
|
Motor encoder (SSI) protocol parameters: Bit rate
150 ... [300] ... 1000 kbps
–
Setting can only be changed if the inverter is disabled.
|
To enable a stable transmission rate, the length of the encoder cable used and any electromagnetic interference levels must be taken into account when setting the value.
|
|
|
0x2C4A:002
|
Motor encoder (SSI) protocol parameters: Telegram length
1 ... [25] ... 31
–
Setting can only be changed if the inverter is disabled.
|
The set value specifies the number of data bits which are transmitted as a complete SSI data packet.
|
|
|
0x2C4A:003
|
Motor encoder (SSI) protocol parameters: Bits/revolution
1 ... [13] ... 31
–
Setting can only be changed if the inverter is disabled.
|
Resolution of the encoder.
For example, the resolution for the preset value is "13":
213 = 8196 (bits/revolution).
|
|
|
0x2C4A:004
|
Motor encoder (SSI) protocol parameters: Position data start bit
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
|
Indicates the position in the telegram where the position data word begins.
|
|
|
0x2C4A:005
|
Motor encoder (SSI) protocol parameters: Data package 1 start bit
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
|
Indicates the position in the telegram where data packet 1 begins.
|
|
|
0x2C4A:006
|
Motor encoder (SSI) protocol parameters: Data package 2 start bit
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
|
Indicates the position in the telegram where data packet 2 begins.
|
|
|
0x2C4A:007
|
Motor encoder (SSI) protocol parameters: Data package 3 start bit
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
|
Indicates the position in the telegram where data packet 3 begins.
|
|
|
0x2C4A:008
|
Motor encoder (SSI) protocol parameters: Position data length
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
|
SSI position data length
|
|
|
0x2C4A:009
|
Motor encoder (SSI) protocol parameters: Data package 1 length
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
|
Length of data packet 1.
|
|
|
0x2C4A:010
|
Motor encoder (SSI) protocol parameters: Data package 2 length
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
|
Length of data packet 2.
|
|
|
0x2C4A:011
|
Motor encoder (SSI) protocol parameters: Data package 3 length
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
|
Length of data packet 3.
|
|
|
0x2C4A:012
|
Motor encoder (SSI) protocol parameters: Position data coding
–
Setting can only be changed if the inverter is disabled.
|
Coding of position data word (read only).
If a value of "0" is set for the position data length in 0x2C4A:008, then the value displayed for this parameter is also "0".
|
|
|
0
|
Binary
|
||
|
1
|
Gray
|
||
|
0x2C4A:013
|
Motor encoder (SSI) protocol parameters: Data package 1 coding
–
Setting can only be changed if the inverter is disabled.
|
Coding of data packet 1
|
|
|
0
|
Binary
|
||
|
1
|
Gray
|
||
|
0x2C4A:014
|
Motor encoder (SSI) protocol parameters: Data package 2 coding
–
Setting can only be changed if the inverter is disabled.
|
Coding of data packet 2
|
|
|
0
|
Binary
|
||
|
1
|
Gray
|
||
|
0x2C4A:015
|
Motor encoder (SSI) protocol parameters: Data package 3 coding
–
Setting can only be changed if the inverter is disabled.
|
Coding of data packet 3
|
|
|
0
|
Binary
|
||
|
1
|
Gray
|
||
|
0x2C4A:016
|
Motor encoder (SSI) protocol parameters: Position raw data
–
Read only
|
Raw value of position data word (read only).
If a value of "0" is set for the position data length in
0x2C4A:008
, then the value displayed for this parameter is also "0".
|
|
|
0x2C4A:017
|
Motor encoder (SSI) protocol parameters: Data package 1 raw data
–
Read only
|
Raw value of data packet 1 (read only).
If a value of "0" is set for the data packet length 1 in 0x2C4A:013
, then the value displayed for this parameter is also "0".
|
|
|
0x2C4A:018
|
Motor encoder (SSI) protocol parameters: Data package 2 raw data
–
Read only
|
Raw value of data packet 2 (read only).
If a value of "0" is set for the data packet length 2 in
0x2C4A:014
, then the value displayed for this parameter is also "0".
|
|
|
0x2C4A:019
|
Motor encoder (SSI) protocol parameters: Data package 3 raw data
–
Read only
|
Raw value of data packet 3 (read only).
If a value of "0" is set for the data packet length 3 in
0x2C4A:015
, then the value displayed for this parameter is also "0".
|
|
|
0x2C4A:020
|
Motor encoder (SSI) protocol parameters: Encoder type
–
Setting can only be changed if the inverter is disabled.
|
||
|
0
|
Rotative encoder
|
||
|
1
|
Linear encoder
|
||
|
0x2C4A:021
|
Motor encoder (SSI) protocol parameters: Position raw data scaled by 0x608F
–
Read only
|
||
|
0x2C4A:022
|
Motor encoder (SSI) protocol parameters: Monoflop time
0 ... [0] ... 500
–
Setting can only be changed if the inverter is disabled.
|
||
|
0x2C4A:023
|
Motor encoder (SSI) protocol parameters: Resulting SSI-telegram cycle time
–
Read only
|
||