Response times of the safety unit

The overall system must be taken into account when determining the response time following a safety function request.
 
Response time of encoder monitoring
Time required to detect faults caused by continuous signal errors at the encoder interface.
[ms]
Default setting
50
Parameterizable via:
0x2878:004
12/50/100
It must be evaluated for each application what minimum response time is possible.
The longer the reaction time, the more the safe speed is filtered.
During dynamic processes (acceleration, deceleration), the safely evaluated speed (nSD) lags behind the actual speed of the drive (nBD) (displayed in 0x287B:006). This time offset must be taken into account when reaching limit values.
 
 
Response times of safe SBC brake control
Response time from the detection of the SBC safety function to the switch-off of the safe brake control
[ms]
tbr
Delay time between request and activation of the brake control
Parameterizable via:
0 ... 30000
ti
Processing time in drive-based safety sensor technology
4
Control X106 starts after
tbr + ti
Test pulse interval and error response time
[ms]
Test pulse interval, brake control
100
Error response time, min. time for error detection and error triggering
200
 
FSoE communication response times
Information on how to calculate the processing time and transmission time of the safety bus can be found in the documentation of the safety PLC used.
Response time to a status word from the safety module (input data)
[ms]
T_Input
T_I
Internal transfer time of the FSoE data from the safety module to the safe control system
8
Tab. 1: Response time to status word
Response time to a control word (output data)
[ms]
T_Output
T_O
Internal transfer time of the FSoE data from the safe control to the safety module
16
Tab. 2: Response time to a control word
If safety bus communication is disturbed, the system switches to the fail-safe state after the safety bus monitoring time (T_WD) has elapsed. Communication via the safety bus is deactivated.