Compensating for inverter influence
Conditions for the execution
–
The motor may be stalled.
–
The inverter is switched on and error-free.
Response of the motor during performance
If the motor is not braked, the motor will move slightly
Disabling the inverter serves to abort the started procedure any time if required. Already determined characteristic values are rejected in this case.
How to detect the inverter characteristic:
1.
Disable the servo inverter.
2.
Change to the "inverter characteristic: identification" operating mode.
0x2825 = 8
0x2825 = 83.
Enable the servo inverter.
The procedure starts.
After the successful completion, the inverter is automatically disabled and the points of the detected inverter characteristic
are set in parameter 0x2947t.
1.
Save the changed settings.
2.
The inverter characteristic must only be detected again if the servo inverter, the motor or the
motor cable have been replaced.
3.
The inverter disable set by the procedure can be deactivated via the control word.
0x6040 = 7
0x6040 = 7Parameter
In the event of an error
If an error occurs during the procedure or the pulse inhibit gets active (e.g. due to short-time undervoltage), the procedure is terminated with inverter disable without the settings being changed.