Diagnostics

Parameter
Address
Name / setting range / [default setting]
Information
0x2C56
Number of the absolute ascertainable revolutions of load encoder/master encoder
–
Read only
 
Is set by the firmware according to the available version:
–
0: no absolute value encoder (sin/cos encoder) or resolver with number of pole pairs > 1
 
–
1: Hiperface encoder SingleTurn or resolver with number of pole pairs = 1
 
–
> 1: Hiperface encoder Multi Turn
 
0x2C5F
Parameter CRC of load encoder/master encoder
–
Read only
 
Display of the cyclic redundancy check (CRC) of selected encoder parameters to detect changes in the feedback settings.
0x2DDF:006
Axis information: Detected module in slot B
–
Read only
 
Display of the supported feedback system for the application.
Cannot be used as motor feedback.
0
Product defined
1
No module
2
Resolver
3
SinCos/HIPERFACE®/SSI
4
SinCos/HIPERFACE®/SSI/TTL
5
I/O extension
6
SinCos/HIPERFACE®/SSI/TTL/EnDat®
7
I/O + HTL extension
0x60E4:001
Additional position actual value: Load encoder/master encoder - actual position
–
Read only
 
Display of the actual position of the secondary feedback system.
0x60E5:001
Additional velocity actual value: Load encoder/master encoder - actual speed
–
Read only: rpm
 
Display of the actual velocity of the secondary feedback system.