General settings

This chapter provides information on general feedback system settings for the application.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2C55
Load encoder/master encoder error response
Selection of the response to the triggering of the encoder signal loss monitoring.
Only active when used as:
–
Feedback system for motor control if set,
 
–
Signal source for the "position counter" function.
 
Associated event ID:
–
537490180 | 0x20097304 - Error - Load encoder/master encoder
 
0
No response
1
Fault > CiA402
2
Warning
0x2C56
Number of the absolute ascertainable revolutions of load encoder/master encoder
–
Read only
 
Is set by the firmware according to the available version:
–
0: no absolute value encoder (sin/cos encoder) or resolver with number of pole pairs > 1
 
–
1: Hiperface encoder SingleTurn or resolver with number of pole pairs = 1
 
–
> 1: Hiperface encoder Multi Turn
 
0x2C57
Open circuit detection sensitivity of load encoder/master encoder
1 ... [100] ... 100 %
The sensitivity can be reduced by percentage, e. g. in case of EMC interferences.
0x60E6:001
Additional position encoder resolution - encoder increments: Load encoder/master encoder - number of increments
–
Setting can only be changed if the inverter is disabled.
 
Setting the number of bits to be used for resolving a mechanical revolution of the secondary feedback system.
65536
16 Bit
262144
18 Bit
1048576
20 Bit
4194304
22 Bit
16777216
24 Bit
67108864
26 Bit
268435456
28 Bit
1073741824
30 Bit
0x60EB:001
Additional position encoder resolution - motor revolutions: Load encoder/master encoder - resolution of motor revolutions
1 ... [1] ... 1
–
Setting can only be changed if the inverter is disabled.
 
Setting of the number of revolutions of the secondary feedback system.
Only setting "1" is accepted.