Suppress diagnostic messages to the IO controller

0x285A:001 serves to set which error response in the device suppresses the alarm message to the IO-Controller.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x285A:001
Diagnostic configuration: Alarm suppression
0x0000 ... [0x0000] ... 0xFFFF
Bit coded selection of error responses which suppress the alarm message to the IO controller.
–
Bit x = 1 = suppress alarm message.
 
–
In the default setting "0", an alarm message is displayed for all error responses.
 
Bit  1
Warning
Bit  2
Warning locked
Bit  3
Trouble
Bit  4
Fault > Application quick stop > Quick stop
Bit  5
Fault > inverter quick stop > quick stop
Bit  6
Fault > inverter quick stop > inverter disabled
Bit  7
Fault > inverter disabled
Bit  8
Fault > CiA402