Station name and IP configuration
The station name and the IP configuration can be assigned by the IO-Controller. These settings enable the IO-Controllerto identify the devices in the network and manage the data exchange.
The station name and the IP configuration can also be assigned by the »Engineering Tool«.
–
The station name of the IO device must be entered with permissible characters according to the PROFINET specification.
0x2381:004
0x2381:004–
Display of the currently used station name:
0x2382:004
0x2382:004–
The IP configuration comprises the assignments of:
–
Display of the actual IP configuration:
0x2382:001 ... 0x2382:003
0x2382:001 ... 0x2382:003Save the station name and the IP configuration in the IO Device with line voltage failure protection so the IO Device can be identified via PROFINET if the IO controller is switched off. 0x2022:003
An invalid station name or the assignment of invalid combinations of the IP address, subnet mask, and gateway address can have the consequence that no connection to PROFINET can be established.
In case of impermissible settings, the red LED "bus ERR" is blinking and the error message "PROFINET: Stack initialization error [0x8192]" is output.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2381:001
|
PROFINET settings: IP address
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
|
Set IP address
–
A changed value will only be effective after the PROFINET communication is restarted (0x2380 = 1).
|
|
|
0x2381:002
|
PROFINET settings: Subnet
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
|
Set subnet mask
–
A changed value will only be effective after the PROFINET communication is restarted (0x2380 = 1).
|
|
|
0x2381:003
|
PROFINET settings: Gateway
0.0.0.0 ... [0.0.0.0] ... 255.255.255.255
|
Set gateway address
–
A changed value will only be effective after the PROFINET communication is restarted (0x2380 = 1).
–
The gateway address is valid if the network address of the IP address is identical to the gateway address. In this case, no gateway functionality is used.
–
DHCP is not supported.
|
|
|
0x2381:004
|
PROFINET settings: Station name
|
Set station name
–
A changed value will only be effective after the PROFINET communication is restarted (0x2380 = 1).
|
|
|
0x2381:005
|
PROFINET settings: I&M1 System designation
|
Input/output of the I&M1 system designation
–
The default setting is an empty string.
|
|
|
0x2381:006
|
PROFINET settings: I&M1 Installation site
|
Input/output of the I&M1 location identification code
–
The default setting is an empty string.
|
|
|
0x2381:007
|
PROFINET settings: I&M2 Installation date
|
Input/output of the I&M2 date of installation
–
The default setting is an empty string.
|
|
|
0x2381:008
|
PROFINET settings: I&M3 additional information
|
Input/output of the I&M3 additional information
–
The default setting is an empty string.
|
|
|
0x2381:009
|
PROFINET settings: I&M4 signature code
["000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"]
|
Input/output of the I&M4 signature
–
The default setting is an empty string.
|
|