Monitoring the pole position identification

If an error occurs during the pole position identification or if the pulse inhibit gets active (e.g. due to a short-time undervoltage), the process is stopped with disabling the inverter without the settings being changed.
If the motor was braked or blocked during the process, this will be detected at the end of the measurement and no change will be made (exception: "pole position identification PLI (without movement)").
The error response can be parameterised:
 
If an error occurs during the pole position identification,
–
the procedure is stopped without the settings being changed.
 
–
the response set in 0x2C60 is effected.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2C60
PPI monitoring: Response
Selection of the response triggered by the occurrence of an error during the pole position identification (PLI).
Associated event IDs:
–
537526020 | 0x2009FF04 - PPI - Motor movement too large
 
–
537526035 | 0x2009FF13 - Identification aborted
 
0
No response
1
Fault > CiA402
2
Warning