Encoder slip compensation
If slip between the motor encoder and load encoder is to be expected due to operation, e.g. in the case of a friction wheel drive, the slip can be cyclically evaluated and compensated for by this function.
The function is intended especially for the travel ranges outside the buffer zones. The function leads to a reduction in buffer end areas and serves to improve the availability of the system.
Slip compensation can also be permanently activated independently of a safety function.
It can be deactivated for the areas between the diagnostic positions and the end of the travel path by setting the appropriate parameters.
WARNING!The slip compensation may not be suitable for the application.
Serious injuries when exceeding the travel path.
▶
As part of the risk assessment for the machine, make sure that the application is suitable for slip compensation.
▶
Traverse the diagnostics markers cyclically when using the slip compensation.
▶
Define a diagnostics interval with the help of the risk assessment. The diagnostics interval must be determined via a master control component.
Preconditions
–
It must be ensured that the boundary to the impermissible area A is not crossed.
Therefore, the buffer end range must be increased by the maximum compensated slip (range B).
Therefore, the buffer end range must be increased by the maximum compensated slip (range B).
–
The maximum compensated slip must be parameterized. 0x2885:001 > 0
This setting activates the slip compensation.
This setting activates the slip compensation.
–
Upper and lower diagnostic position must be parameterized. 0x2884:002, 0x2884:003
Fig. 1: End zone using the example of the PDSS safety function
A
Prohibited area
B
Buffer end zone
Functional description
–
For slip compensation, the diagnostic positions
①
and ②
are required so that the freedom from error of the load encoder is verified cyclically.–
To ensure that sufficient braking distance is available in the event of an error, it must be ensured that the diagnostic positions are arranged in such a way that error detection takes place in the range of the maximum permissible speed.
–
The cycle for traversing the diagnostic positions must be controlled by the application. The cycle must be monitored in terms of safety.
–
Between the diagnostic positions
①
and ②
, a cyclic position comparison is performed between the motor encoder and load encoder in each calculation cycle of the safety function.–
The diagnostic positions must be located in front of the buffer areas at the ends of the travel path:
Fig. 2: Position of the diagnostic marks using the example of the PDSS safety function
–
When traversing the diagnostic positions, the diagnostic position is compared with the current absolute value encoder position.
–
If the difference is outside the parameterized tolerance window, the parameterized error reaction is triggered.