0x2110:014
|
Delete home position
|
Command: Deletion of the safe reference in order to set a new reference.
|
|
0
|
Ready
|
|
|
1
|
Start
|
|
2
|
In progress
|
|
3
|
Action cancelled
|
|
4
|
No access
|
|
0x2880:001
|
SHom_Start: Source
–
Safety parameter (+Safety parameter list+)
|
Selection of the trigger source for the function.
|
|
0
|
Disabled
|
|
|
13
|
S-Bus
|
|
14
|
IRS
|
|
0x2880:002
|
SHom_Start: IRS edge trigger
–
Safety parameter (+Safety parameter list+)
|
Selection of the edge evaluation for the IRS reference input.
|
|
0
|
Rising edge
|
|
|
1
|
Falling edge
|
|
0x2881:001
|
SHom_Load: Source
–
Safety parameter (+Safety parameter list+)
|
Selection of the trigger source for the function.
|
|
13
|
S-Bus
|
|
|
15
|
IRL
|
|
0x2881:002
|
SHom_Load: IRL edge trigger
–
Safety parameter (+Safety parameter list+)
|
Selection of the edge evaluation for the IRL reference input.
|
|
0
|
Rising edge
|
|
|
1
|
Falling edge
|
|
0x2882:001
|
SHom: Home position
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
|
Setting of the safe home position, which is taken over at SHOM_Load.
It is the absolute reference point for the SLP, SCA and PDSS safety functions.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
|
|
0x2882:002
|
SHom: Timeout
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
|
The parameterized home mark must be detected within this monitoring time after SHom_Start.
|
|
0x2882:003
|
SHom: SLS for homing
–
Safety parameter (+Safety parameter list+)
|
Selection of the SLS function that is active during homing.
|
|
3
|
SLS1
|
|
|
4
|
SLS2
|
|
5
|
SLS3
|
|
6
|
SLS4
|
|
0x2882:004
|
SHom: Restart condition
–
Safety parameter (+Safety parameter list+)
|
Setting specifying whether safe homing is required after the restart.
|
|
0
|
Homing required
|
|
|
1
|
Load saved reference
|
|
0x2882:005
|
SHom: Starting position tolerance
0 ... [0] ... 327680 incr.
–
Safety parameter (+Safety parameter list+)
|
Permitted tolerance between the safe position that is saved and the current safe position after restarting.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
|
|
0x2882:006
|
SHom: Status
|
Status of the safe reference.
|
|
0
|
No reference
|
|
|
1
|
SHom active
|
|
2
|
SHom available
|
|
3
|
Mini-homing active
|
|
0x2882:007
|
SHom: Saved position
|
Safe position saved at the last switch-off.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
|
|
0x2883
|
SHom Source diagnostic positions
–
Safety parameter (+Safety parameter list+)
|
Selection of the trigger source for the function.
|
|
0
|
Disabled
|
|
|
1
|
SD-In1
|
|
2
|
SD-In2
|
|
3
|
SD-In3
|
|
4
|
SD-In4
|
|
14
|
IRS
|
|
15
|
IRL
|
|
0x2884:001
|
SHom: Level diagnostic positions
–
Safety parameter (+Safety parameter list+)
|
Selection of the level for detecting a SHom diagnostic position.
|
|
0
|
LOW level
|
|
|
1
|
HIGH level
|
|
0x2884:002
|
SHom: Lower diagnostic position
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
|
Setting of the lower SHom diagnostic position.
|
|
0x2884:003
|
SHom: Upper diagnostic position
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
|
Setting of the upper SHom diagnostic position.
|
|
0x2884:004
|
SHom: Tolerance diagnostic positions
0 ... [0] ... 327680 incr.
–
Safety parameter (+Safety parameter list+)
|
Setting of the permissible tolerance when traversing the SHom diagnostic positions.
|
|
0x2884:005
|
SHom: Error response diagnostic positions
–
Safety parameter (+Safety parameter list+)
|
Response to errors detected in the function.
|
|
0
|
STO
|
|
|
1
|
SS1
|
|
2
|
SS2
|
|
0x2884:006
|
SHom: Current difference diagnostic position
|
Display of the current difference when passing a SHom diagnostic position.
|
|
0x2885:001
|
SHom: Maximum compensated slip
0 ... [0] ... 327680 incr.
–
Safety parameter (+Safety parameter list+)
|
Setting of the maximum slip compensated per motor revolution.
The setting 0 Incr. deactivates the function.
|
|
0x2885:002
|
SHom: End area slip compensation
–
Safety parameter (+Safety parameter list+)
|
Selection of whether slip compensation is active in the end ranges outside the diagnostic positions
|
|
0
|
Disabled
|
|
|
1
|
Activated
|
|
0x2886
|
SHom "SHom active" - Output
–
Safety parameter (+Safety parameter list+)
|
Selection of the safe output for the "SHom active" feedback.
|
|
0
|
Disabled
|
|
|
1
|
SD-Out1 positive logic
|
|
2
|
SD-Out1 negative logic
|
|
0x2887
|
SHom "SHom available" - Output
–
Safety parameter (+Safety parameter list+)
|
Selection of the safe output for the "SHom available" feedback.
|
|
0
|
Disabled
|
|
|
1
|
SD-Out1 positive logic
|
|
2
|
SD-Out1 negative logic
|