Supported measured values
The standardised measured values are supported:
|
ID
|
Measured value
|
Description
|
|
34
|
Active power in W
|
Active power
Corresponds to the current value from parameter 0x2DA2:001.
|
|
205
|
Active energy sum in kWh
|
Energy sum
Corresponds to the current value from parameter 0x2DA3:003.
The value can be reset by writing "0".
|
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2DA2:001
|
Output power: Effective power
–
Read only: x.xxx kW
|
Display of the active output power for an energy analysis in the respective application.
|
|
|
0x2DA3:003
|
Output energy: Overall energy
-21474836.47 ... [0.00] ... 21474836.47 kWh
|
Display of the energy balance:
–
Positive values: Energy consumed
–
Negative values: Generated energy
0x2DA3:003 = 0 resets the energy balance.
When replacing a device, the value of the old device can be adopted as the starting value for the new device.
|
|