One cable technology (OCT) via HIPERFACE DSL®

Fig. 1: Example setup HIPERFACE DSL® (OCT)
 
Preconditions
–
The One Cable Technology is only available in the devices < 22 kW.
 
–
The One Cable Technology (OCT) is possible with MCS and m850 servo motors.
 
–
The motor must be provided with a HIPERFACE DSL® encoder.
 
–
Make sure that no motor encoder module is plugged in slot A.
 
–
Connection cable
 
–
The EYP008xxxxxxM11A00 or EYP008xxxxxxM12A00 hybrid cable must be used.
 
–
Different lengths up to 100 m are available.  
 
–
The hybrid cables have only basic insulation to the power electronics.
 
 
 
Application range
The use of One Cable Technology (OCT) depends on the combination of the basic device firmware with the safety firmware:
Use of One Cable Technology (OCT)
Basic device firmware
As of V01.06.04
V01.05.03
V01.05.02
V01.04.02
V01.04.01
V01.03.07
V01.02.03
​V01.01.03
Safety firmware
As of ​V01.03.03​
​V01.02.03
​V01.02.03
V01.02.03​​
​​V01.02.03​
​​V01.01.01​
​​V01.00.01
​​-
With device variant
"Basic Safety - STO"
●​
●​
●​
●​
●​
●​
​​-
​​-
"Extended Safety"
●
​-
​​-
​​-
​​-
​​-
​​-
​​-
 
Parameterize HIPERFACE DSL® (OCT)
Parameter Axis settings: Function X109 = 10 to activate HIPERFACE DSL® (OCT). 0x2DE1:001
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2DE1:001
Axis settings: Function of X109
0
None
10
HIPERFACE DSL® (OCT)
20
PTC
0x2C4B:001
Motor encoder (HDSL): Release version
–
Read only
 
0x2C4B:002
Motor encoder (HDSL): Release Date
–
Read only
 
0x2C4B:003
Motor encoder (HDSL): Encoder ID
–
Read only
 
0x2C4B:004
Motor encoder (HDSL): Type of encoder
–
Read only
 
0x2C4B:005
Motor encoder (HDSL): Resolution
–
Read only
 
0x2C4B:006
Motor encoder (HDSL): Measurement range
–
Read only
 
0x2C4B:007
Motor encoder (HDSL): Type name
–
Read only
 
0x2C4B:008
Motor encoder (HDSL): Serial number
–
Read only
 
0x2C4B:009
Motor encoder (HDSL): Device version
–
Read only
 
0x2C4B:010
Motor encoder (HDSL): Firmware date
–
Read only
 
0x2C4B:011
Motor encoder (HDSL): EEPROM size
–
Read only
 
0x2C4B:012
Motor encoder (HDSL): Safe Channel 2 Resolution
–
Read only
 
0x2C4B:020
Motor encoder (HDSL): Delay / RSSI
–
Read only
 
Bit  0
Cable delay, bit 0
Bit  1
Cable delay, bit 1
Bit  2
Cable delay, bit 2
Bit  3
Cable delay, bit 3
Bit  4
RSSI, bit 0
Bit  5
RSSI, bit 1
Bit  6
RSSI, bit 2
Bit  7
RSSI, bit 3
0x2C4B:021
Motor encoder (HDSL): Quality monitoring
–
Read only
 
Bit  0
QM, bit 0
Bit  1
QM, bit 1
Bit  2
QM, bit 2
Bit  3
QM, bit 3
Bit  7
LINK
0x2C4B:022
Motor encoder (HDSL): Slave RSSI
–
Read only
 
Bit  0
SRSSI, bit 0
Bit  1
SRSSI, bit 1
Bit  2
SRSSI, bit 2
0x2C4B:023
Motor encoder (HDSL): Supply voltage
–
Read only: x.xxx V
 
0x2C4B:024
Motor encoder (HDSL): Rotation speed range
–
Read only: x rpm
 
0x2C4B:025
Motor encoder (HDSL): Auswahl
0
No value
1
Lifetime
2
Sensor monitor
3
Rotation speed
4
Temperature
0x2C4B:026
Motor encoder (HDSL): Value
–
Read only
 
0x2C4B:027
Motor encoder (HDSL): Communication error counter
–
Read only
 
0x2C4B:040
Motor encoder (HDSL): Events
–
Read only
 
Bit  1
FREL: Channel free for "long message"
Bit  2
QMLW: Quality monitoring low value warning
Bit  4
ANS: Erroneous answer to "long message"
Bit  5
MIN: Message initialization
Bit  8
PRST: Protocol reset warning
Bit  9
DTE: Estimator Deviation Threshold Error
Bit  11
POS: Estimator turned on
Bit  14
SUM: Remote event monitoring
Bit  15
INT: Interrupt status
0x2C4B:041
Motor encoder (HDSL): Status summaries
–
Read only
 
Bit  0
SUM0
Bit  1
SUM1
Bit  2
SUM2
Bit  3
SUM3
Bit  4
SUM4
Bit  5
SUM5
Bit  6
SUM6
Bit  7
SUM7
0x2C4B:042
Motor encoder (HDSL): Encoder status, byte 0
–
Read only
 
Bit  0
Encoder status bit 0
Bit  1
Encoder status bit 1
Bit  2
Encoder status bit 2
Bit  3
Encoder status bit 3
Bit  4
Encoder status bit 4
Bit  5
Encoder status bit 5
Bit  6
Encoder status bit 6
Bit  7
Encoder status bit 7
0x2C4B:043
Motor encoder (HDSL): Encoder status, byte 1
–
Read only
 
Bit  0
Encoder status bit 8
Bit  1
Encoder status bit 9
Bit  2
Encoder status bit 10
Bit  3
Encoder status bit 11
Bit  4
Encoder status bit 12
Bit  5
Encoder status bit 13
Bit  6
Encoder status bit 14
Bit  7
Encoder status bit 15
0x2C4B:044
Motor encoder (HDSL): Encoder status, byte 2
–
Read only
 
Bit  0
Encoder status bit 16
Bit  1
Encoder status bit 17
Bit  2
Encoder status bit 18
Bit  3
Encoder status bit 19
Bit  4
Encoder status bit 20
Bit  5
Encoder status bit 21
Bit  6
Encoder status bit 22
Bit  7
Encoder status bit 23
0x2C4B:045
Motor encoder (HDSL): Encoder status, byte 3
–
Read only
 
Bit  0
Encoder status bit 24
Bit  1
Encoder status bit 25
Bit  2
Encoder status bit 26
Bit  3
Encoder status bit 27
Bit  4
Encoder status bit 28
Bit  5
Encoder status bit 29
Bit  6
Encoder status bit 30
Bit  7
Encoder status bit 31
0x2C4B:046
Motor encoder (HDSL): Encoder status, byte 4
–
Read only
 
Bit  0
Encoder status bit 32
Bit  1
Encoder status bit 33
Bit  2
Encoder status bit 34
Bit  3
Encoder status bit 35
Bit  4
Encoder status bit 36
Bit  5
Encoder status bit 37
Bit  6
Encoder status bit 38
Bit  7
Encoder status bit 39
0x2C4B:047
Motor encoder (HDSL): Encoder status, byte 5
–
Read only
 
Bit  0
Encoder status bit 40
Bit  1
Encoder status bit 41
Bit  2
Encoder status bit 42
Bit  3
Encoder status bit 43
Bit  4
Encoder status bit 44
Bit  5
Encoder status bit 45
Bit  6
Encoder status bit 46
Bit  7
Encoder status bit 47
0x2C4B:048
Motor encoder (HDSL): Encoder status, byte 6
–
Read only
 
Bit  0
Encoder status bit 48
Bit  1
Encoder status bit 49
Bit  2
Encoder status bit 50
Bit  3
Encoder status bit 51
Bit  4
Encoder status bit 52
Bit  5
Encoder status bit 53
Bit  6
Encoder status bit 54
Bit  7
Encoder status bit 55
0x2C4B:049
Motor encoder (HDSL): Encoder status, byte 7
–
Read only
 
Bit  0
Encoder status bit 56
Bit  1
Encoder status bit 57
Bit  2
Encoder status bit 58
Bit  3
Encoder status bit 59
Bit  4
Encoder status bit 60
Bit  5
Encoder status bit 61
Bit  6
Encoder status bit 62
Bit  7
Encoder status bit 63
0x2C4B:050
Motor encoder (HDSL): Fast position
–
Read only