One cable technology (OCT) via HIPERFACE DSL®
Fig. 1: Example setup HIPERFACE DSL® (OCT)
Preconditions
–
The One Cable Technology is only available in the devices < 22 kW.
–
The One Cable Technology (OCT) is possible with MCS and m850 servo motors.
–
The motor must be provided with a HIPERFACE DSL® encoder.
–
Make sure that no motor encoder module is plugged in slot A.
–
Connection cable
–
The EYP008xxxxxxM11A00 or EYP008xxxxxxM12A00 hybrid cable must be used.
–
Different lengths up to 100 m are available.
–
The hybrid cables have only basic insulation to the power electronics.
Application range
The use of One Cable Technology (OCT) depends on the combination of the basic device firmware with the safety firmware:
|
|
Use of One Cable Technology (OCT)
|
||||||||
|
Basic device firmware
|
As of V01.06.04
|
V01.05.03
|
V01.05.02
|
V01.04.02
|
V01.04.01
|
V01.03.07
|
V01.02.03
|
V01.01.03
|
|
|
Safety firmware
|
As of V01.03.03
|
V01.02.03
|
V01.02.03
|
V01.02.03
|
V01.02.03
|
V01.01.01
|
V01.00.01
|
-
|
|
|
With device variant
|
|
||||||||
|
|
"Basic Safety - STO"
|
●
|
●
|
●
|
●
|
●
|
●
|
-
|
-
|
|
|
"Extended Safety"
|
●
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
Parameterize HIPERFACE DSL® (OCT)
Parameter Axis settings: Function X109 = 10 to activate HIPERFACE DSL® (OCT).
0x2DE1:001
0x2DE1:001Parameter