Extended Safety
PROFIsafe output data
The safety controller transmits PROFIsafe output data (control commands) to the inverter:
–
Data length: 16 bytes
–
Control commands are LOW-active, the bit state "0" activates the function.
–
Exceptions: See details in the table.
|
Byte offset
|
Bit offset
|
|||||||
|
Bit 7
|
Bit 6
|
Bit 5
|
Bit 4
|
Bit 3
|
Bit 2
|
Bit 1
|
Bit 0
|
|
|
Byte 0
|
SDIpos
|
SLS4
|
SLS3
|
SLS2
|
SLS1
|
SS2
|
SS1
|
STO
|
|
Byte 1
|
SLP4
|
SLP3
|
SLP2
|
SLP1
|
OMS
(HIGH-active)
|
SLI
|
ES
(HIGH-active)
|
SDIneg
|
|
Byte 2
|
SSE
|
PDSS
|
SHom load
(0↗1)
|
SHom start
(0↗1)
|
RMS
(HIGH-aktiv)
|
SOS
|
AIE
(0↗1)
|
AIS
(0↗1)
|
|
Byte 3
|
-
|
-
|
-
|
-
|
-
|
-
|
SBC
|
SD-Out1
(HIGH-active)
|
|
Byte 4
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
Byte 5
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
Byte 6
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
Byte 7
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
Byte 8
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
Byte 9
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
Byte 10
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
Byte 11
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
Byte 12
|
Status byte
|
|||||||
|
Byte 13
|
CRC2 (consecutive number)
|
|||||||
|
Byte 14
|
||||||||
|
Byte 15
|
||||||||
PROFIsafe input data
The inverter transmits PROFIsafe input data (status information) to the safety controller:
–
Data length: 16 bytes
–
Status information is HIGH-active, the bit status "1" indicates the active status information.
|
Byte offset
|
Bit offset
|
|||||||
|
Bit 7
|
Bit 6
|
Bit 5
|
Bit 4
|
Bit 3
|
Bit 2
|
Bit 1
|
Bit 0
|
|
|
Byte 0
|
SDIpos active
|
SLS4 active
|
SLS3 active
|
SLS2 active
|
SLS1 active
|
SS2 active
|
SS1 active
|
STO active
|
|
Byte 1
|
SLP4 observed
|
SLP3 observed
|
SLP2 observed
|
SLP1 observed
|
SOS active
|
SLI active
|
ES active
|
SDIneg active
|
|
Byte 2
|
SSE active
|
SDIneg observed
|
SDIpos observed
|
SLS4 observed
|
SLS3 observed
|
SLS2 observed
|
SLS1 observed
|
SOS observed
|
|
Byte 3
|
Error active
|
SMS observed
|
OMS active
|
RMS active
|
SD-In4
|
SD-In3
|
SD-In2
|
SD-In1
|
|
Byte 4
|
SCA4 within limits
|
SCA3 within limits
|
SCA2 within limits
|
SCA1 within limits
|
PDSSneg observed
|
PDSSpos observed
|
SHom vorhanden
|
SHom active
|
|
Byte 5
|
MUT active
|
SBC activated
|
SBC active
|
SD-Out1
|
Positive direction
|
n = 0
|
Safe speed OK
|
SSM within limits
|
|
Byte 6
|
Actual speed n_safe, byte 0
|
|||||||
|
Byte 7
|
Actual speed n_safe, byte 1
|
|||||||
|
Byte 8
|
Actual position p_safe, byte 0
|
|||||||
|
Byte 9
|
Actual position p_safe, byte 1
|
|||||||
|
Byte 10
|
Actual position p_safe, byte 2
|
|||||||
|
Byte 11
|
Actual position p_safe, byte 3
|
|||||||
|
Byte 12
|
Status byte
|
|||||||
|
Byte 13
|
CRC2 (consecutive number)
|
|||||||
|
Byte 14
|
||||||||
|
Byte 15
|
||||||||