Extended Safety
PROFIsafe output data
The safety controller transmits PROFIsafe output data (control commands) to the inverter:
–
Data length: 16 bytes
 
–
Control commands are LOW-active, the bit state "0" activates the function.
 
–
Exceptions: See details in the table.
 
Byte offset
Bit offset
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
SDIpos
SLS4
SLS3
SLS2
SLS1
SS2
SS1
STO
Byte 1
SLP4
SLP3
SLP2
SLP1
OMS
(HIGH-active)
SLI
ES
(HIGH-active)
SDIneg
Byte 2
SSE
PDSS
SHom load
(0↗1)
SHom start
(0↗1)
RMS
(HIGH-aktiv)
SOS
AIE
(0↗1)
AIS
(0↗1)
Byte 3
-
-
-
-
-
-
SBC
SD-Out1
(HIGH-active)
Byte 4
-
-
-
-
-
-
-
-
Byte 5
-
-
-
-
-
-
-
-
Byte 6
-
-
-
-
-
-
-
-
Byte 7
-
-
-
-
-
-
-
-
Byte 8
-
-
-
-
-
-
-
-
Byte 9
-
-
-
-
-
-
-
-
Byte 10
-
-
-
-
-
-
-
-
Byte 11
-
-
-
-
-
-
-
-
Byte 12
Status byte
Byte 13
CRC2 (consecutive number)
Byte 14
Byte 15
 
PROFIsafe input data
The inverter transmits PROFIsafe input data (status information) to the safety controller:
–
Data length: 16 bytes
 
–
Status information is HIGH-active, the bit status "1" indicates the active status information.
 
Byte offset
Bit offset
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
SDIpos active
SLS4 active
SLS3 active
SLS2 active
SLS1 active
SS2 active
SS1 active
STO active
Byte 1
SLP4 observed
SLP3 observed
SLP2 observed
SLP1 observed
SOS active
SLI active
ES active
SDIneg active
Byte 2
SSE active
SDIneg observed
SDIpos observed
SLS4 observed
SLS3 observed
SLS2 observed
SLS1 observed
SOS observed
Byte 3
Error active
SMS observed
OMS active
RMS active
SD-In4
SD-In3
SD-In2
SD-In1
Byte 4
SCA4 within limits
SCA3 within limits
SCA2 within limits
SCA1 within limits
PDSSneg observed
PDSSpos observed
SHom vorhanden
SHom active
Byte 5
MUT active
SBC activated
SBC active
SD-Out1
Positive direction
n = 0
Safe speed OK
SSM within limits
Byte 6
Actual speed n_safe, byte 0
Byte 7
Actual speed n_safe, byte 1
Byte 8
Actual position p_safe, byte 0
Byte 9
Actual position p_safe, byte 1
Byte 10
Actual position p_safe, byte 2
Byte 11
Actual position p_safe, byte 3
Byte 12
Status byte
Byte 13
CRC2 (consecutive number)
Byte 14
Byte 15