Extended Safety
FSoE output data
The safety controller transmits FSoE output data (control commands) to the inverter:
–
Data length: 11 bytes
 
–
Control commands are LOW-active, the bit state "0" activates the function.
 
–
Exceptions: See details in the table.
 
Byte offset
Bit offset
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
Command (CMD)
Byte 1
AIE
(0↗1)
SDIneg
SDIpos
-
SOS
SS2
SS1
STO
Byte 2
SSE
SLI
ES
(HIGH-active)
RMS
(HIGH-active)
OMS
(HIGH-active)
SHom load
(0↗1)
SHom start
(0↗1)
AIS
(0↗1)
Byte 3
CRC_0 (low-byte)
Byte 4
CRC_0 (high-byte)
Byte 5
SLP4
SLP3
SLP2
SLP1
SLS4
SLS3
SLS2
SLS1
Byte 6
-
-
-
-
-
SBC
SD-Out1
(HIGH-active)
PDSS
Byte 7
CRC_1 (Low-Byte)
Byte 8
CRC_1 (High-Byte)
Byte 9
Connection-ID (low-byte)
Byte 10
Connection-ID (high-byte)
 
FSoE input data
The inverter transmits FSoE input data (status information) to the safety controller:
–
Data length: 31 bytes
 
–
Status information is HIGH-active, the bit status "1" indicates the active status information.
 
Byte offset
Bit offset
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
Command (CMD)
Byte 1
Error active
SDIneg active
SDIpos active
-
SOS active
-
-
STO active
Byte 2
SSE active
SLI active
ES active
RMS active
OMS active
SOS observed
SS2 active
SS1 active
Byte 3
CRC_0 (low-byte)
Byte 4
CRC_0 (high-byte)
Byte 5
SLS4 observed
SLS3 observed
SLS2 observed
SLS1 observed
SLS4 active
SLS3 active
SLS2 active
SLS1 active
Byte 6
SCA4 within limits
SCA3 within limits
SCA2 within limits
SCA1 within limits
SLP4 observed
SLP3 observed
SLP2 observed
SLP1 observed
Byte 7
CRC_1 (low-byte)
Byte 8
CRC_1 (high-byte)
Byte 9
SSM within limits
SMS observed
PDSSneg observed
PDSSpos observed
SDIneg observed
SDIpos observed
SHom available
SHom active
Byte 10
-
-
-
-
MUT active
Positive direction
n=0
Safe speed OK
Byte 11
CRC_2 (low-byte)
Byte 12
CRC_2 (high-byte)
Byte 13
-
-
-
-
SD-In4
SD-In3
SD-In2
SD-In1
Byte 14
-
-
-
-
-
SBC activated
SBC active
SD-Out1
Byte 15
CRC_3 (low-byte)
Byte 16
CRC_3 (high-byte)
Byte 17
Actual speed n_safe, byte 0
Byte 18
Actual speed n_safe, byte 1
Byte 19
CRC_4 (low-byte)
Byte 20
CRC_4 (high-byte)
Byte 21
Actual position p_safe, byte 0
Byte 22
Actual position p_safe, byte 1
Byte 23
CRC_5 (low-byte)
Byte 24
CRC_5 (high-byte)
Byte 25
Actual position p_safe, byte 2
Byte 26
Actual position p_safe, byte 3
Byte 27
CRC_6 (low-byte)
Byte 28
CRC_6 (high-byte)
Byte 29
Connection-ID (low-byte)
Byte 30
Connection-ID (high-byte)