Important notes
DANGER!
No "emergency switching off" in terms with EN 60204-1
With the "Safe torque off" (STO) function, no "emergency switching off" in terms with EN 60204-1 can be executed without additional measures. There is no electrical isolation between the motor and inverter and no service switch or maintenance switch!
Possible consequences: Death or severe injuries
▶
"Emergency switching off" requires electrical isolation, e. g. by a central mains contactor.
 
 
 
DANGER!
The power supply is not safely disconnected.
Possible consequences: Death or severe injuries due to electrical voltage.
▶
Turn off the power supply.
 
 
 
DANGER!
Uncontrolled rotation of the motor possible.
Possible consequences: Death or severe injuries
▶
Set the motor to standstill mechanically.
 
 
 
DANGER!
Automatic restart can occur if the request of the safety function is deactivated.
Possible consequences: Death or severe injuries
▶
You must provide external measures according to EN ISO 13849-1 which ensure that the drive only restarts after a confirmation.