Virtual mode

The application can be tested without a connected motor. For this purpose, the setpoint selection for the drive can be interrupted.
When the virtual mode is active, the setpoints generated in the application are not transmitted to the drive. The actual values (e. g. position and velocity) are generated from the setpoints.
The kinematic parameters do not have any influence in the virtual mode. Only the parameters travel range and cycle length are used for the machine measuring system.
Machine measuring system parameters
–
Travel range 0x500A:030
 
–
Cycle length 0x500B:031
 
For diagnostic purposes, an active virtual mode is displayed in the Status word parameter. 0x500A:005 Bit 0
 
Parameter
Address
Name / setting range / [default setting]
Information
0x500A:029
Virtual mode
–
Setting can only be changed if the inverter is disabled.
 
false
Inactive
true
Active