Outputs

The following parameters are available for the diagnostics of the system bus output values:
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5021:160
System bus diagnostics: Cycle length (output value)
–
Read only
 
Cycle length of the source set via Master value output of system bus 0x5020:001.
0x5021:161
System bus diagnostics: Position (output value)
–
Read only
 
Master position value of the source set via Master value output of system bus 0x5020:001.
0x5021:162
System bus diagnostics: Velocity (output value)
–
Read only
 
Master speed value of the source set via Master value output of system bus 0x5020:001.
0x5021:163
System bus diagnostics: Acceleration (output value)
–
Read only
 
Master acceleration value of the source set via Master value output of system bus 0x5020:001.
0x5021:164
System bus diagnostics: Torque (output value)
–
Read only: x.xxxx Nm
 
Torque of the master axis of the source set via Master value output of system bus 0x5020:001.
0x5021:165
System bus diagnostics: Time stamp (output value)
–
Read only: x ns
 
Time stamp of the touchprobe source in ns selected via source TP1 0x5020:011.
0x5021:166
System bus diagnostics: Output data word 6
–
Read only
 
This system bus input word is currently not used, but can be connected in the technology application by the user.
0x5021:167
System bus diagnostics: Output data word 7
–
Read only