Source of touch probe time stamp
The Source touch probe system bus parameter is used to set the source of the touch probe time stamp.
0x5020:011
0x5020:011Fig. 1: Selection of the source of the touch probe time stamp
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x5020:011
|
TP1 source
|
The sensor source and the edge to be evaluated are selected via the parameter (rising, falling, any)
|
|
|
0
|
External source
|
Source: System bus
|
|
|
1
|
Digital input 1, positive edge
|
|
|
|
2
|
Digital input 1, negative edge
|
|
|
|
3
|
Digital input 1, any edge
|
|
|
|
11
|
Digital input 2, positive edge
|
|
|
|
12
|
Digital input 2, negative edge
|
|
|
|
13
|
Digital input 2, any edge
|
|
|
|
21
|
Digital input 3, positive edge
|
|
|
|
22
|
Digital input 3, negative edge
|
|
|
|
23
|
Digital input 3, any edge
|
|
|
|
31
|
Digital input 4, positive edge
|
|
|
|
32
|
Digital input 4, negative edge
|
|
|
|
33
|
Digital input 4, any edge
|
|
|
|
0x5021:155
|
System bus diagnostics: Time stamp (input value)
–
Read only: x ns
|
Time stamp of the master axis
|
|
|
0x5021:165
|
System bus diagnostics: Time stamp (output value)
–
Read only: x ns
|
Time stamp of the touchprobe source in ns selected via source TP1 0x5020:011.
|
|