Quick stop

The quick stop function is used for stopping the axis and in the event of an error.
The ramp used can be set via the following parameters:
–
 
–
 
If the quick stop function is active, it is displayed in the status word of the technology application. 0x500A:005 Bit 13
The source for the signal for activating quick stop is set under the Application quick stop source parameter. 0x5020:007
Special features
–
The quick stop function starts with the acceleration "0".
Exception: If the axis is already in the deceleration phase, it is started with the active setpoint acceleration to avoid prolonging the existing braking process.
 
–
Setpoint generation for the quick stop function starts at the actual speed.
 
–
During the deceleration it is changed to the speed-controlled operation.
 
–
After reaching standstill, it is changed to the position control.
 
–
During the stop, no torque reduction is effective.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x500A:048
Application quick stop - deceleration
0.01 ... [3600.00] ... 21474836.47
0x500A:049
Application quick stop - jerk
0.00 ... [0.00] ... 21474836.47
0x5020:007
Application quick stop source
Selection of the signal source for activating the quick stop.
0
FALSE
1
TRUE
2
Digital input 1
3
Digital input 2
4
Digital input 3
5
Digital input 4