Target position detection
The target position detection identifies whether the axis is in the symmetrical target position window after the dwell time has elapsed.
The information is provided in the Status word parameter of the technology application.
Under these conditions, the "Axis in target" status (bit 23 = TRUE) is reset to FALSE:
–
The actual position has left the target position window.
–
A new motion task is started.
–
The home position is reset.
0x500A:005