Target position detection

The target position detection identifies whether the axis is in the symmetrical target position window after the dwell time has elapsed.
The information is provided in the Status word parameter of the technology application.
–
Status word — Axis:0x500A:005 Bit 23
 
–
Status word — Virtual master axis:0x500C:005 Bit 23
 
Under these conditions, the "Axis in target" status (bit 23 = TRUE) is reset to FALSE:
–
The actual position has left the target position window.
 
–
A new motion task is started.
 
–
The home position is reset.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x500A:130
Position window size
0.0000 ... [0.0000] ... 214748.3647
0x500A:131
Position window dwell time
0.000 ... [0.000] ... 2147483.647 s
0x500A:135
Modulo positioning tolerance window
0.0000 ... [0.0000] ... 214748.3647