Manual jog (inching mode)

The "manual jog" function enables manual traversing of the drive ("inching mode").
 
"Manual jog" can be activated via 2 control signals in the technology application. "Manual jog" is possible in the positive and negative directions.
–
As long as the control bit is set, the drive moves.
 
–
If both requests are set simultaneously, the drive stops.
 
–
If the reference is known and the software limit switches are activated, positioning to the corresponding software limit switch is carried out.
Exception: If the manual jog has been stopped manually before this by resetting the control inputs, a positioning to the corresponding software limit switch is aborted.
The drive brakes with the set deceleration to the position of the corresponding hardware limit switch.
 
–
If the reference is not known or the software limit switches are not activated, the axis only stops at the hardware limit switch.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x500A:181
Manual jog velocity
0.0000 ... [360.0000] ... 214748.3647
0x500A:182
Manual jog acceleration
0.00 ... [720.00] ... 21474836.47
0x500A:183
Manual jog deceleration
0.00 ... [1440.00] ... 21474836.47
0x500A:184
Manual jog jerk
0.00 ... [0.00] ... 21474836.47