Status signals

Parameter
Address
Name / setting range / [default setting]
Information
0x2DE0:014
Overwrite bit 4 of CiA control word
0
No overwrite
1
Overwrite with FALSE
2
Overwrite with TRUE
0x500A:004
PLCopen status
–
Read only
 
1
ErrorStop
2
Disabled
3
Standstill
4
Stopping
5
DiscMotion
6
SyncMotion
7
ContMotion
8
Homing
10
Service
0x500A:005
Status word
–
Read only
 
Bit  0
Virtual mode active
Bit  1
Axis ready
Bit  2
Axis enabled
Bit  3
Warning active
Bit  4
Error active
Bit  5
Home position detected
Bit  6
Software limit switches enabled
Bit  7
Software limit switch positive
Bit  8
Software limit switch negative
Bit  9
Hardware limit switch positive
Bit  10
Hardware limit switch negative
Bit  11
STO active
Bit  12
Brake opened
Bit  13
Application quick stop active
Bit  14
Limitation active
Bit  16
"Following error" warning active
Bit  17
"Following error" error active
Bit  18
Homing active
Bit  19
Homing switch for touch probe reached
Bit  20
Application torque limits
Bit  21
Manual jog active
Bit  22
Standstill active
Bit  23
Set position reached
Bit  24
Software limit switches switched off
Bit  25
0x500A:010
Actual position
–
Read only
 
0x500A:011
Actual velocity
–
Read only
 
0x500A:012
Actual acceleration
–
Read only
 
0x500A:014
Set position
–
Read only
 
0x500A:015
Velocity setpoint
–
Read only
 
0x500A:016
Acceleration setpoint
–
Read only
 
0x500A:017
Torque setpoint
–
Read only: x.xx Nm
 
0x500B:005
Status word
–
Read only
 
Bit  1
Encoder ready
Bit  3
Warning active
Bit  4
Error active
Bit  5
Home position detected
Bit  22
Standstill active
0x500B:010
Actual position
–
Read only
 
The current position value is resolved with 4 decimal positions.
0x500B:011
Actual velocity
–
Read only
 
The current speed value is resolved with 4 decimal positions.
0x500B:012
Actual acceleration
–
Read only