Virtual master
The technology application allows operation with a virtual master. In this case, a drive in the network takes on the role of the virtual master while at the same time serving as the first slave drive. The generated master value is transmitted to the slave drives via the system bus.
Operating modes
The virtual master provides the following operating modes:
|
Operating mode/function
|
Bit names of the "Simulation of control signals for virtual master" parameter
|
Parameter index
|
Bit
|
|
Continuous operation
|
VM Continuous
|
Bit 25
|
|
|
Clocked operation
|
VM cycle
|
Bit 26
|
|
|
Loading of the starting position
|
Load VM position
|
Bit 27
|
|
|
Manual operation - positive direction of rotation
|
Positive manual operation VM
|
Bit 28
|
|
|
Manual operation - negative direction of rotation
|
Negative manual operation VM
|
Bit 29
|
|
Function
|
Parameter name
|
Parameter index
|
|
Setting of the setpoint velocity
|
Setpoint speed
|
|
|
Guide to standstill position
|
Setpoint position of virtual master
|
|
|
Acceleration to setpoint velocity
|
Acceleration of virtual master
|
|
|
Decelerate master value
|
Deceleration of virtual master
|
|
Function
|
Parameter name
|
Parameter index
|
|
Accelerate
|
Acceleration of manual operation
|
|
|
Manual speed
|
Speed of manual operation
|
|
|
Decelerate
|
Deceleration of manual operation
|
|
|
Parameterize jerk
|
Jerk of manual operation
|
Fig. 1: Virtual master as setpoint source
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2DA4:005
|
Diagnostics of analog input 1: Scaled percent value
–
Read only: x.xx %
|
Display of the actual value at the analog input, scaled with the following parameters:
–
Minimum value for scaling.
0x2636:013–
Maximum value for scaling.
0x2636:014 |
|
|
0x4001
|
Interface selection
|
Selecting the interface determines the interface that receives the signals.
|
|
|
0
|
Fieldbus network
|
Control of the application via the fieldbus.
|
|
|
1
|
Onboard EtherCAT
|
Activation of the application via the system bus.
|
|
|
0x500B:011
|
Actual velocity
–
Read only
|
The current speed value is resolved with 4 decimal positions.
|
|
|
0x5020:009
|
Reference velocity for analog input 1
0.0000 ... [500.0000] ... 214748.3647
|
The reference speed for the percentage value of the analog input.
|
|
|
0x5020:014
|
Master value source
–
Setting can only be changed if the inverter is disabled.
|
||
|
0
|
System bus
|
The system bus provides the external master velocity value.
|
|
|
1
|
Load encoder
|
The signal from the load encoder interface is taken as the master velocity value.
|
|
|
2
|
Virtual master
|
The virtual master, whose setpoint velocity comes from the Set virtual master velocity PDO, serves as master value master.
0x5045:011 |
|
|
3
|
Analog input 1
|
||
|
0x5021:152
|
System bus diagnostics: Velocity (input value)
–
Read only
|
Speed conductivity
|
|
|
0x5042:017
|
Set velocity of selected master value
–
Read only
|
||
|
0x5045:010
|
Virtual master control signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
||
|
Bit
0
|
Control bit 00 (reserved)
|
This bit can be assigned to an optinal function.
|
|
|
Bit
1
|
Control bit 01 (reserved)
|
This bit can be assigned to an optinal function.
|
|
|
Bit
2
|
Control bit 02 (reserved)
|
||
|
Bit
3
|
Control bit 03 (reserved)
|
||
|
Bit
4
|
Control bit 04 (reserved)
|
||
|
Bit
5
|
Control bit 05 (reserved)
|
||
|
Bit
6
|
Control bit 06 (reserved)
|
||
|
Bit
7
|
Fault reset
|
Only after the cause has been eliminated are the errors reset.
|
|
|
Bit
8
|
Control bit 08 (reserved)
|
This bit can be assigned to an optinal function.
|
|
|
Bit
9
|
Control bit 09 (reserved)
|
This bit can be assigned to an optinal function.
|
|
|
Bit
10
|
Control bit 10 (reserved)
|
||
|
Bit
11
|
Control bit 11 (reserved)
|
This bit can be assigned to an optinal function.
|
|
|
Bit
12
|
Control bit 12 (reserved)
|
||
|
Bit
13
|
Control bit 13 (reserved)
|
||
|
Bit
14
|
Control bit 14 (reserved)
|
||
|
Bit
15
|
Control bit 15 (reserved)
|
||
|
Bit
16
|
Control bit 16 (reserved)
|
||
|
Bit
17
|
Control bit 17 (reserved)
|
This bits is not used in the TA.
|
|
|
Bit
18
|
Control bit 18 (reserved)
|
||
|
Bit
19
|
Control bit 19 (reserved)
|
||
|
Bit
20
|
Control bit 20 (reserved)
|
This bit can be assigned to an optinal function.
|
|
|
Bit
21
|
Control bit 21 (reserved)
|
||
|
Bit
22
|
Control bit 22 (reserved)
|
||
|
Bit
23
|
Control bit 23 (reserved)
|
||
|
Bit
24
|
Control bit 24 (reserved)
|
||
|
Bit
25
|
Continuous operation
|
Triggers the continuous driving operation of the virtual master.
|
|
|
Bit
26
|
Cyclic operation
|
||
|
Bit
27
|
Load position
|
Starting position of the virtual master axis loaded.
–
This function can also be executed when the axis is disabled or the virtual master, stop = TRUE.
–
This function cannot be executed during the position synchronisation.
|
|
|
Bit
28
|
Manual jog positive
|
Virtual master moves in the positive direction (manual jog).
|
|
|
Bit
29
|
Manual jog negative
|
Virtual master moves in the negative direction (manual jog).
|
|
|
Bit
30
|
Halt
|
The active movement of the virtual master is aborted and the axis is brought to a standstill with the deceleration defined via the Stop parameter.
|
|
|
Bit
31
|
Deactivate external master values
|
–
The external master values are deactivated.
–
The virtual master is used as the actual value source.
–
The clutch is switched without a jump.
|
|
|
0x5045:011
|
Set velocity
-214748.3648 ... [0.0000] ... 214748.3647
|
The value of the setpoint velocity of the virtual master is given in [units/s]. The value of the setpoint velocity is resolved with 4 decimal places.
|
|
|
0x5045:110
|
Virtual master status signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
||
|
Bit
0
|
Status bit 00 (reserved)
|
This bit of the status signal can be assigned to a function status.
|
|
|
Bit
1
|
Status bit 01 (reserved)
|
This bit of the status signal can be assigned to a function status.
|
|
|
Bit
2
|
Status bit 02 (reserved)
|
||
|
Bit
3
|
Fault
|
||
|
Bit
4
|
Status bit 04 (reserved)
|
This bit of the status signal can be assigned to a function status.
|
|
|
Bit
5
|
Status bit 05 (reserved)
|
This bit of the status signal can be assigned to a function status.
|
|
|
Bit
6
|
Manual jog active
|
Manual operation is activated.
|
|
|
Bit
7
|
Warning
|
The warning is activated.
|
|
|
Bit
8
|
Halt active
|
||
|
Bit
9
|
Status bit 09 (reserved)
|
This bit of the status signal can be assigned to a function status.
|
|
|
Bit
10
|
Status bit 10 (reserved)
|
This bit of the status signal can be assigned to a function status.
|
|
|
Bit
11
|
Status bit 11 (reserved)
|
||
|
Bit
12
|
Status bit 12 (reserved)
|
||
|
Bit
13
|
Status bit 13 (reserved)
|
||
|
Bit
14
|
Status bit 14 (reserved)
|
||
|
Bit
15
|
Status bit 15 (reserved)
|
||
|
Bit
16
|
Status bit 16 (reserved)
|
||
|
Bit
17
|
Status bit 17 (reserved)
|
||
|
Bit
18
|
Status bit 18 (reserved)
|
||
|
Bit
19
|
Status bit 19 (reserved)
|
||
|
Bit
20
|
Status bit 20 (reserved)
|
||
|
Bit
21
|
Status bit 21 (reserved)
|
||
|
Bit
22
|
Status bit 22 (reserved)
|
||
|
Bit
23
|
Status bit 23 (reserved)
|
||
|
Bit
24
|
Status bit 24 (reserved)
|
||
|
Bit
25
|
Busy
|
The virtual master is activated.
|
|
|
Bit
26
|
Taget reached
|
The axis has reached the target position and is at standstill.
0x5046:002 |
|
|
Bit
27
|
Synchronized
|
||
|
Bit
28
|
Synchronization active
|
||
|
Bit
29
|
Status bit 29 (reserved)
|
This bit of the status signal can be assigned to a function status.
|
|
|
Bit
30
|
Status bit 30 (reserved)
|
This bit of the status signal can be assigned to a function status.
|
|
|
Bit
31
|
External master values deactivated
|
The external master value is deactivated in the system bus in the application feedback (B).
|
|
|
0x5045:111
|
Actual position
-214748.3648 ... [0.0000] ... 214748.3647
|
The setpoint position is specified in [unit]. The setpoint position is resolved with 4 decimal places.
|
|
|
0x5045:112
|
Actual velocity
-214748.3648 ... [0.0000] ... 214748.3647
|
The setpoint velocity is specified in [units/s]. The setpoint velocity is resolved with 4 decimal places.
|
|
|
0x5045:113
|
Actual acceleration
-21474836.48 ... [0.00] ... 21474836.47
|
The current position is specified in [unit]. The current position is resolved with 4 decimal places.
|
|
|
0x5045:114
|
Error code
0 ... [0] ... 4294967295
|
The current error number is displayed in the word.
|
|
|
0x5045:115
|
Cycle length
-214748.3648 ... [0.0000] ... 214748.3647
|
The current position is specified in [unit]. The current position is resolved with 4 decimal places.
|
|
|
0x5046:001
|
Virtual master start position
0.0000 ... [0.0000] ... 214748.3647
|
||
|
0x5046:002
|
Virtual master set position
0.0000 ... [0.0000] ... 214748.3647
|
||
|
0x5046:003
|
Virtual master acceleration
0.00 ... [100000.00] ... 21474836.47
|
||
|
0x5046:004
|
Virtual master deceleration
0.00 ... [100000.00] ... 21474836.47
|
||
|
0x5046:005
|
Virtual master jerk
0.00 ... [1000000.00] ... 21474836.47
|
||
|
0x5046:020
|
Virtual master clutch velocity
0.0000 ... [100.0000] ... 214748.3647
|
||
|
0x5047:001
|
Virtual Master: Set velocity
–
Read only
|
||
|
0x500C:004
|
PLCopen status
–
Read only
|
||
|
1
|
Error Stop
|
||
|
2
|
Disabled
|
||
|
3
|
Standstill
|
||
|
4
|
Stopping
|
||
|
5
|
DiscMotion
|
||
|
6
|
SyncMotion
|
||
|
7
|
ContMotion
|
||
|
8
|
Homing
|
||
|
10
|
Service
|
||
|
0x500C:005
|
Status word
–
Read only
|
||
|
Bit
0
|
Virtual mode active
|
||
|
Bit
1
|
Axis ready
|
||
|
Bit
2
|
Axis enabled
|
||
|
Bit
3
|
Warning active
|
||
|
Bit
4
|
Error active
|
||
|
Bit
5
|
Home position reached
|
||
|
Bit
6
|
Software limit switches enabled
|
||
|
Bit
7
|
Positive software limit switch reached
|
||
|
Bit
8
|
Negative software limit switch reached
|
||
|
Bit
13
|
Application quick stop active
|
||
|
Bit
14
|
Limitation active
|
||
|
Bit
18
|
Homing active
|
||
|
Bit
19
|
Homing switch for touch probe reached
|
||
|
Bit
20
|
|
||
|
Bit
21
|
Manual jog active
|
||
|
Bit
22
|
Standstill active
|
||
|
Bit
23
|
Set position reached
|
||
|
Bit
24
|
Software limit switches switched off
|
||
|
Bit
25
|
|
||
|
0x500C:010
|
Actual position
–
Read only
|
||
|
0x500C:011
|
Actual velocity
–
Read only
|
||
|
0x500C:012
|
Actual acceleration
–
Read only
|
||
|
0x500C:014
|
Set position
–
Read only
|
||
|
0x500C:015
|
Velocity setpoint
–
Read only
|
||
|
0x500C:016
|
Set acceleration
–
Read only
|
||
|
0x500C:030
|
Traversing range
–
Setting can only be changed if the inverter is disabled.
|
Specification of the traversing range for the virtual master axis.
–
0: Linearly limited traversing range (spindle drive).
–
1: Unlimited traversing range (turntable). The cycle length must also be specified here.
|
|
|
0
|
Modulo
|
||
|
1
|
Limited
|
||
|
0x500C:031
|
Cycle length
0.0001 ... [360.0000] ... 214748.3647
–
Setting can only be changed if the inverter is disabled.
|
The cycle length for an unlimited traversing range defines at which position the measuring system is repeated (position return to 0).
|
|
|
0x500C:045
|
Max. velocity
0.0000 ... [0.0000] ... 214748.3647
|
||
|
0x500C:046
|
Max. acceleration
0.00 ... [0.00] ... 21474836.47
|
||
|
0x500C:047
|
Max. jerk
0.00 ... [0.00] ... 21474836.47
|
||
|
0x500C:048
|
Application quick stop - deceleration
0.01 ... [3600.00] ... 21474836.47
|
||
|
0x500C:049
|
Application quick stop - jerk
0.00 ... [0.00] ... 21474836.47
|
||
|
0x500C:050
|
Enable software limit switches
|
||
|
false
|
Inactive
|
||
|
true
|
Active
|
||
|
0x500C:051
|
Software limit switch positive
-214748.3648 ... [0.0000] ... 214748.3647
|
||
|
0x500C:052
|
Software limit switch negative
-214748.3648 ... [0.0000] ... 214748.3647
|
||
|
0x500C:053
|
Action after "software limit switch reached"
|
||
|
0
|
Stop after software limit switch
|
||
|
1
|
Stop at software limit switch
|
||
|
0x500C:105
|
Response to "software limit switch reached"
|
||
|
19
|
Fault > Application quick stop > Quick stop
|
||
|
21
|
Fault> Application quick stop > Inverter disabled
|
||
|
0x500C:106
|
Response to "profile limit reached"
|
||
|
0
|
No Response
|
||
|
2
|
Warning
|
||
|
19
|
Fault > Application quick stop > Quick stop
|
||
|
21
|
Fault> Application quick stop > Inverter disabled
|
||
|
0x500C:150
|
SLS1
0.0000 ... [0.0000] ... 214748.3647
|
||
|
0x500C:151
|
SLS1 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
|
||
|
0x500C:152
|
SLS2
0.0000 ... [0.0000] ... 214748.3647
|
||
|
0x500C:153
|
SLS2 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
|
||
|
0x500C:154
|
SLS3
0.0000 ... [0.0000] ... 214748.3647
|
||
|
0x500C:155
|
SLS3 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
|
||
|
0x500C:156
|
SLS4
0.0000 ... [0.0000] ... 214748.3647
|
||
|
0x500C:157
|
SLS4 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
|
||
|
0x500C:162
|
Deactivate safety interface
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
||
|
Bit
1
|
Ignore SS1 request
|
||
|
Bit
2
|
Ignore SS2 request
|
||
|
Bit
3
|
Ignore SLS1 - SLS4 request
|
||
|
Bit
4
|
Ignore SDI request
|
||
|
Bit
5
|
|
||
|
0x500C:163
|
Limiter call
–
Read only
|
||
|
Bit
0
|
STO active
|
||
|
Bit
1
|
SS1 active
|
||
|
Bit
2
|
SS2 active
|
||
|
Bit
3
|
SOS active
|
||
|
Bit
4
|
SLS1 active
|
||
|
Bit
5
|
SLS2 active
|
||
|
Bit
6
|
SLS3 active
|
||
|
Bit
7
|
SLS4 active
|
||
|
Bit
8
|
SDIpos active
|
||
|
Bit
9
|
SDIneg active
|
||
|
0x500C:181
|
Manual jog velocity
0.0000 ... [360.0000] ... 214748.3647
|
||
|
0x500C:182
|
Manual jog acceleration
0.00 ... [720.00] ... 21474836.47
|
||
|
0x500C:183
|
Manual jog deceleration
0.00 ... [1440.00] ... 21474836.47
|
||
|
0x500C:184
|
Manual jog jerk
0.00 ... [0.00] ... 21474836.47
|
||
|
0x500C:186
|
Deceleration of Halt
0.00 ... [1800.00] ... 21474836.47
|
||
|
0x500C:187
|
Jerk of Halt
0.00 ... [0.00] ... 21474836.47
|
||
0x2636:013