Disable operation Master value sources
The source of the master value can only be switched over when the inverter is disabled.
Disable operation
Disable operation The master values for the technology application come from a variety of sources. The source is selected via the Master value source parameter.
0x5020:014
0x5020:014The following sources can be selected:
–
System bus
–
Application feedback (B)
–
Virtual master
–
Analog input 1
Fig. 1: Selection of the master value source
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x5020:014
|
Master value source
–
Setting can only be changed if the inverter is disabled.
|
||
|
0
|
System bus
|
The system bus provides the external master velocity value.
|
|
|
1
|
Load encoder
|
The signal from the load encoder interface is taken as the master velocity value.
|
|
|
2
|
Virtual master
|
The virtual master, whose setpoint velocity comes from the Set virtual master velocity PDO, serves as master value master.
0x5045:011 |
|
|
3
|
Analog input 1
|
||
0x5045:011